C2.19 Change the position of rule-
set “Disconnect_WAN” to be the topmost by clicking the arrow-icon
C2.20
Click button “Apply settings” to activate the new firewall-filter
Important:
Before testing the CUT function we have to determine how to re-activate a disconnected WAN port. This has
to be done in the menu Cut & Alarm.
C2.21 Select menu Configuration
Cut & Alarm
By default a triggered CUT or Alarm event has to be
re-set
manually as shown below left. To re-set manually
triggered events change to tab State and click buttons “Reset cut signal” and/or “Reset alarm signal”
Tab
“Configuration”
Tab
“State”
Alternatively the
re-set
of events can be configured automatically with a selectable time-delay.
The 2 screenshots below show a configured “automatic mode”