From the perspective of an addressed receiver in the production network the sender has always the
public
IP address.
7. Configuring static routes (Only for Router 3
, skip if you test the”Ssimple scenario” with only 1 Router)
Next 2 static routes have to be configured on Router 3 that all Ethernet devices of machine networks networks 1
and 2 (behind LAN port of Routers 1 and 2) can get access to each other.
► Select menu
Configuration
Network
IP routing
Tab “Configuration”
Figure A4-8
: Default values of menu
IP routing (Tab Configuration)
Configure below described entries in the area
Add new static route
of the menu:
Only for Router 3
(This Router has 2 static routes)
Values for the first route:
● Destination network:
192.168.20.0 (Public address range of machine network 1 at LAN port of Router 1)
● Subnet mask :
24 (Class C)
● Gateway:
172.16.1.252 (Public address of WAN port of Router 1)
● Metric:
Can be left blank (only one route, therefore no need for prioritization)
● Interface:
LAN