Copyright © 2013 Weidmüller Interface GmbH & Co. KG
84 / 103
All rights reserved. Reproduction without permission is prohibited.
Figure A5-3
: Menu
IP routing (Tab State)
showing the new active routing table
Testing the accessibility between Ethernet Devices of network 1 and 2
1. Send a ping request from Machine 1 of Network 1 to Machine 1 of Network 2
Send “ping 192.168.21.100”
(this ist the public IP address of Machine 1 of Network 2, translated by
1:1 NAT from 192.168.1.100 to from 192.168.21.100)
1. Send a ping request from Machine 1 of Network 2 to Machine 1 of Network 1
Send “ping 192.168.20.100”
(this ist the public IP address of Machine 1 of Network 1, translated by
1:1 NAT from 192.168.1.100 to from 192.168.20.100)
Result: All s
ent “pings” should be answered by the requested IP addresses correctly.
Note:
1.
If you perform the ping test using PC’s please check your firewall configuration to ensure that ping
requests and echoes are allowed.
2. Keep in mind that every device which will be used for ping testing needs an entry for the standard gateway
(IP address is pointing to the Router of the PC’s network).