Copyright © 2013 Weidmüller Interface GmbH & Co. KG
91 / 103
All rights reserved. Reproduction without permission is prohibited.
C2.12
Select “Action” = Cut + Drop
C2.13 Enable checkboxes Log and Alarm to signalize a CUT in the Event-Log and to switch-on the
Alarm-LED at frontside of the Router
C2.14 Enter the name of the rule (max. 15 characters)
C2.15
Click button “Next”
Now the rule “LinkDownByPing” is created. We do not need any further rules.
C2.16 Click button Next to finish creating the rule-set
C2.17
Click button “OK” cause we do not set any time limits