User Relay Setup
The User Relay Setup menu allows the user to control the relays.
Each relay has a normally open and a normally closed contact. Off means de-energized (normal contact states). On means
energized (opposite of normal contact states).
There may be one or two relays displayed here depending upon the alarm relay usage. One relay is reserved for alarms
unless the user configures it to be used for user relay application. This is done via the serial port in terminal mode or the
diagnostics interface of the web interface. The command “alarmrelay user2” will assign the relay for user application and the
command “alarmrelay normal” will assign the relay for alarms. When assigned for alarms, this relay will be normally
energized and will be de-energized in the case of an alarm.