I
P
UMP
562
U
SER
’
S
M
ANUAL
2
800092-02 Rev. C
www.wegener.com
Environmental Operating Conditions and Physical Specifications
Item/Limit
Specification
Use Indoor
Altitude
Up to 3048 meters
Temperature Range
10
o
C to 40
o
C
Relative Humidity (max.)
80% for temperatures up to 31
o
C decreasing linearly to 50% relative
humidity at 40
o
C
Weight
7.5 pounds or 3.4019 kilograms
Dimensions (H x W x D)
1RU (1.75"x 16.5"x 11.5" or 44.45 mm x 419.1 mm x 292.1 mm)
Input Power Rating for iPump 562
12VDC 5.0A
Input Power Rating for inline power
supply
100-240VAC, 50/60Hz, 1.5A
Rear Panel Connections
iPump 562
rear panel view
iPump 562
Rear Panel Connections
Signal
Connector
Description
DC IN
Male Power Jack
+12 VDC @ 5A
RF IN - Port 1
Type F
950 to 2150 MHz signal accepted. LNB power and Universal/Astra
signaling available
RF IN - Port 2, 3, 4
Type F
(Optional) 950 to 2150 MHz signal accepted.
RS232 Port
RJ-12
Serial Asynchronous Data. May be used for terminal or printer
Audio OUT 2 (L/R)
2 RCA Phono Jacks Audio (stereo or mono L/R assignable)
GPIO
DB-9
Two Relays rated at 0.1A @ 30 V DC and one GPIO input for
triggered file play.
Composite Video
RCA Phono Jack
Composite Video NTSC or PAL
C-Video
RCA Phono Jack
Composite Video NTSC or PAL
Component Video
3 RCA Phono Jacks Component SD/HD Video YPbPr