Installation and Connection
3
3-22 | UR11
NOTE!
Make sure the CFW-11M inverter has the 2.0x software version or above. For more details, refer to
the "CFW-11M user manual" and the "CFW-11 programming manual".
and
show that the DIM1 and DIM2 digital
inputs are set to "Without External Rectifier Fault" (P0832 = 6) and "Without External Rectifier Overtemperature"
(P0833 = 4) respectively. On both examples, the CFW-11M will show F414 ("External Rectifier Fault") if DIM1
input (and therefore the RL1 output relay - "UCD1_OK / UDC2_OK" - of the CIR11) opens when the DC
bus voltage is higher than the undervoltage level and the CFW-11M PWM is enabled; or it will display F412
("External Rectifier Overtemperature") if DIM2 input (and therefore the output relay RL3 - "Without Temperature
Fault" - of CIR11) opens.
shows DIM1 and DIM2 digital inputs set to "Without External Rectifier Alarm"
(P0832 = 5) and "Without External Rectifier Overtemperature Fault" (P0833 = 4), respectively. In this case,
the CFW-11M will display A415 ("External Rectifier High Temperature" alarm) if the DIM1 (and therefore the
RL2 relay output - "Without Temperature Alarm" - of CIR11) opens, and it will display F412 ("External Rectifier
Overtemperature") if the DIM2 input (and therefore the RL3 relay output - "Without Temperature Fault" - of
CIR11) opens.
* NO - normally open contact.
C - common.
NC - normally closed contact.
+24 V
GND_+24 V
(P0832 = 5)
(P0833 = 4)
J1
PE
PE
XC2
XC3
XC1
XC2
NA1
DIM1
DIM2
COM
COM
NA2
NA3
NF1
NF2
NF3
C1
C2
C3
CIR11
IPS1
UR11
UC11 (CFW11M)
2
3
4
4
4
4
5
5
5
5
6
7
8
9
1
Figure 3.24 -
Application example with active high signal at the DIs of the CFW-11M