QUICK REFERENCE OF PARAMETERS AND FAULTS
Param.
Description
Adjustable range
Factory
setting
Page
Analog output gain AO1 MVC3
0.000 to 9.999
1.000
MVC3 AO2 Funct.
0 to 511
5
Analog output gain AO2 MVC3
0.000 to 9.999
1.000
MVC3 AO3 Funct.
0 to 511
2
Analog output gain AO3 MVC3
0.000 to 9.999
1.000
MVC3 AO4 Funct.
0 to 511
5
Analog output gain AO4 MVC3
0.000 to 9.999
1.000
Analog output offset AO1 MVC3
-32768 to 32767
-90
Analog output offset AO2 MVC3
-32768 to 32767
-90
Analog output offset AO3 MVC3
-32768 to 32767
-90
Analog output offset AO4 MVC3
-32768 to 32767
-90
Analog input AI5 function
0 = P221/P222
0
Analog input AI5 gain (bipolar isolated
MVC4 board)
0.000 to 9.999
1.000
Analog input AI5 signal type
0 = 0-10V/20mA
1 = 4 - 20 mA
2 = 10V/20mA-0
3 = 20 - 4 mA
0
Analog input AI5 offset (bipolar isolated
MVC4 board)
0.0 to 100.0 %
0.0 %
Minimum coasting time
0 to 300 s
0 s
Function of analog input AI1 MVC3
0 = Not Used
1 = Torque reference
2 = Limit current
0
Analog input AI1 gain (bipolar MVC3
board)
0.000 to 9.999
1.000
Analog input AI1 offset (bipolar MVC3
board)
-100.0 to 100.0 %
0.0 %
Function of analog input AI2 MVC3
0 = Not Used
1 = Field current
0
Analog input AI2 gain (bipolar MVC3
board)
0.000 to 9.999
1.000
Analog input AI2 offset (bipolar MVC3
board)
-100.0 to 100.0 %
0.0 %
Motor Type
0 = Induction motor
1 = Reserved
2 = Brushless synchronous motor
0
Direction of rotation of the speed sensor
0 = Reverse
1 = Direct
1
DC link voltage of cell U1
Read-only parameter (V)
-
DC link voltage of cell U2
Read-only parameter (V)
-
DC link voltage of cell U3
Read-only parameter (V)
-
DC link voltage of cell U4
Read-only parameter (V)
-
DC link voltage of cell U5
Read-only parameter (V)
-
MVW3000 | 1-23