5
DETAILED PARAMETER DESCRIPTION
Description:
It defines the function of the AI2 analog input of the MVC3 board.
Table 5.72:
Function of analog input AI2 MVC3
Function
0
Not Used
1
Field current
P0745 - Analog input AI2 gain (bipolar MVC3 board)
Adjustable range:
0.000 to 9.999
Factory setting:
1.000
Acesso:
Menu
→
Configurations
→
I/O
→
Analog inputs
Description:
It sets the gain of analog input AI2 of the MVC3 board.
Refer to P0234 (Analog input AI1 gain (unipolar MVC4 board)).
P0746 - Analog input AI2 offset (bipolar MVC3 board)
Adjustable range:
-100.0 to 100.0 %
Factory setting:
0.0 %
Acesso:
Menu
→
Configurations
→
I/O
→
Analog inputs
Description:
It sets the offset of analog input AI2 of the MVC3 board.
Refer to P0234 (Analog input AI1 gain (unipolar MVC4 board)).
P0950 - Motor Type
Adjustable range:
0 to 2
Factory setting:
0
Acesso:
Menu
→
Configurations
→
Control
Description:
It selects the type of the motor to be driven by the inverter, where each option presents specific configuration
parameters.
Table 5.73:
Motor Type
Function
0
Induction motor
1
Reserved
2
Brushless synchronous motor
✓
NOTE!
This parameter can be changed only with the motor stopped.
P0957 - Direction of rotation of the speed sensor
Adjustable range:
0 to 1
Factory setting:
1
Acesso:
Menu
→
Configurations
→
Control
MVW3000 | 5-97
Summary of Contents for MVW3000 Series
Page 2: ......
Page 58: ...1 QUICK REFERENCE OF PARAMETERS AND FAULTS MVW3000 1 52...
Page 62: ...2 SAFETY INSTRUCTIONS MVW3000 2 4...
Page 192: ...6 SPECIAL FUNCTIONS MVW3000 6 4...
Page 262: ...7 DIAGNOSTICS AND TROUBLESHOOTING MVW3000 7 70...
Page 263: ......