2
English
To fix the encoder and prepare the connection cable of the electric signals, follow
the instructions of item 3.
For the correct installation of modules ENC-01 and ENC-02, follow the steps
below:
step 1:
With the inverter de-energized, remove the front cover of the CFW11
(figure 2);
step 2:
Carefully plug-in the module into slot 2 (figure 3
(a)
);
step 3:
Place and tighten the grounding screw and fixture of the module
(figure 3
(b)
);
step 4:
Set the module switches as shown in table 1;
step 5:
Connect the encoder cables to connector XC4 of modules ENC-01 and
ENC-02.
Figure 2:
Removal of front cover
Figure 3:
Installation of optional module into slot
b
c
a
a