3
English
Figure 4 :
Characteristics and signals of cables and connectors
2. ConFiGURaTions
Table 1:
Module ENC-01 and ENC-02 configuration switches
Switches
Function
Position
Operation
Observations
S1:1
External source voltage for
the encoder repeater circuit
(ENC-01-only)
ON
5V (By-pass internal
voltage regulator)
-
OFF
(*)
7V to 24V (internal vol-
tage regulator active)
-
S1:2
Not connected internally
-
-
-
S2:1
Failure detection on signals
Z, Z (F079)
ON
(*)
Failure detection
enable
-
OFF
Failure detection
disabled
Turn OFF when
the encoder does
not have signals Z
and Z
S2:2
Failure detection on
encoder signals A, A, B, B,
Z, Z (F079)
ON
Failure detection
disabled
Does not depend
on the S2:1 status
OFF
(*)
Failure detection
enable
-
S3:1
Encoder voltage supply
ON
5Vdc
Set according to
the voltage of the
encoder used
OFF
(*)
12Vdc
S3:2
Not connected internally
-
-
-
S1:1 and
S1:2
S2:1 and
S2:2
S3:1 and
S3:2
(*) Factory standard.
Summary of Contents for ENC-01