PARAMETERS SETTING: (2ND LEVEL)
S2
Hold down the button for 3 seconds to gain access to the 2nd level menu.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
S2
Press this button to scroll the list of settings to edit.
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S3) to save the setting and quit the menu.
Tab. 8 - Parameters of the 2nd level menu: MMA mode
ACRONYM
PARAMETER
MIN DEFAULT MAX
EL.
ELECTRODE TYPE
bAS
bAS
ALU
bAS= basic
rUt= rutile
Crn= chromium/nickel
ALU= aluminium
Urd
OUTPUT VOLTAGE REDUCTION oFF
oFF
on *2
U.EL.
LONG ARC VOLTAGE
37
*SYn
70
Tab. 9 - Parameters of the 2nd level menu: DESEAMING mode
ACRONYM
PARAMETER
MIN DEFAULT MAX
Urd
OUTPUT VOLTAGE REDUCTION oFF
oFF
on *3
Tab. 10 - Parameters of the 2nd level menu: CONTINUOUS DC TIG mode, PULSED DC TIG mode, SYNERGIC DC TIG mode
ACRONYM
PARAMETER
MIN DEFAULT MAX
SP.t.
SPOT TIG TIME
0.01 s 0.01 s 15.0 s
HF
HF ARC STRIKE ENABLE oFF
on
on
r.P.C.
MINIMUM PEDAL CURRENT 1 %
5 %
90 %
4.7
PARAMETERS SETTING: SPECIAL FUNCTIONS
S1
Press this button to scroll the list of settings to edit.
The acronym relative to the setting to be edited appears on the following displays: D1
The value relative to the selected setting appears on the following displays: D2
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S1) to save the setting and quit the menu.
Tab. 11 - SPECIAL FUNCTIONS menu parameters: CONTINUOUS DC TIG mode, PULSED DC TIG mode
ACRONYM PARAMETER MIN DEFAULT MAX
q.St.
Q-START
0.1 s
oFF
10.0 s
d.Ar.
DYNAMIC ARC 1
oFF
50
M.tA.
MULTI TACK 0.5 Hz
oFF
6.0 Hz *1
Tab. 12 - SPECIAL FUNCTIONS menu parameters: SYNERGIC DC TIG mode
ACRONYM PARAMETER MIN DEFAULT MAX
M.tA.
MULTI TACK 0.5 Hz
oFF
6.0 Hz *1
*1:
When this function is active welding is performed without the following parameters:
SLOPE UP - SLOPE DOWN - STARTING CURRENT - FINAL
CURRENT
*2:
The activation is suitable for the following welding modes:
MMA - DESEAMING MODE
*SYN: This code indicates that parameters control is synergic.
The optimal value of this parameter is set automatically by the microprocessor on the basis of the preset welding current value.
When SYN is installed, to display the synergic value press the following button: S5
This value can be displayed but it is not user-adjustable.