Cod.006.0001.1680
24/04/2014 v2.0
ENGLISH
Cruiser 402 T - Cruiser 502 T
Power Pulse 402 T - Power Pulse 502 T
6/50
6. Connector for connection to the programmer.
(Programming connector for the "frontal logic" circuit board)
You can update the software of the equipment using the
programming kit.
7. Connector of the bundle of cables for connecting the power source
to the remote control device.
8. Power cable.
Total length (including internal part): 5,0 m
Number and cross section of wires: 4 x 2,5 mm
2
Power plug type: not supplied
9. Socket for connecting the power cable between the power source
and the remote control device.
2.4
PREPARING FOR MMA WELDING
1. Set the welding power source ON/OFF switch to “O” (unit de-
energized).
2. Plug the power cable plug into a mains socket outlet.
3. Choose the electrode based on the type of material and thickness
of the workpiece to be welded.
4. Insert the electrode in the electrode holder.
5. Connect the electrode holder cable to the welding socket based on
the polarity requested by the type of electrode used.
6. Connect the plug of the ground clamp to the welding socket on the
basis of the polarity required.
7. Connect the earth clamp to the workpiece being processed.
DANGER!
Electric shock hazard!
Read the warnings highlighted by the following symbols in the
“General prescriptions for use”.
8. Set the welding power source ON/OFF switch to “I” (unit
powered).
9. Select the following welding mode on the user interface: MMA
10. Set the required welding parameter values on the user interface.
When the remote controller [RC] is connected and the relative
locking screw is tightened, welding current can be adjusted using
the remote controller.
The system is ready to start welding.