Webasto Frigo Top 10 Workshop Manual Download Page 3

Frigo Top 10 - 43 | Pordoi 2000 - 4000 3 

1  About this document

1.1  Purpose of the document

This workshop manual is used to support instructed personnel 
when adjusting the parameters of the control element for trans-
port refrigeration.

1.2  Using this document

 

X

Read this document before changing parameters.

 

X

Read the operating instructions.

1.3  Use of symbols and highlighting

Explanation

Action to be taken.

Requirements for the following necessary action.

Note on a special technical feature.

Separate information is available.

ATTENTION:

 Possibility on property damage.

WARNING:

 Possibility on minor or moderate injury.

DANGER:

 Possibility on a severe or mortal injury.

1.4  Warranty and liability

Webasto shall not assume liability for defects or damage that are 
the result that the installation, operating instructions and as well 
as the instructions contained therein being disregarded.
This liability exclusion particularly applies for:

 

Improper use

 

Repairs not carried out by a Webasto service workshop

 

Use of non-genuine parts

 

Conversion of the unit without permission from Webasto

 

Mechanical damage to the equipment

 

Failure to comply with inspection and maintenance instructions

ATTENTION
Misuse as a result of failure to comply with the 
workshop manual

Result: damage to the refrigeration system

 

X

 Follow the operating instructions and instructions 
described in this document.

2  Safety

2.1  General safety

The repair and commissioning personnel must have the following 
qualifications:

 

Successful completion of Webasto training.

 

Corresponding qualification for working on technical systems.

 

Certified to work on air conditioning systems.

The repair and installation of the unit may only be carried out in 
accordance with the workshop manual and the installation in-
structions.

2.2  Intended use

The system is designed for cooling the load compartment of com-
mercial vehicles while driving. 

The performance values of your application are 
closely related to ambient conditions, vehicle insula-
tion, etc. The actual temperature may therefore de-
viate from the set value. 

In the case of vehicles fitted with automatic start-
stop control, the function must be switched off 
while operating the refrigeration system. For infor-
mation on the control and function of the automat-
ic start-stop control, please read the operating in-
structions for your vehicle.

2.3  Versions

 

Fresh produce delivery system:  
Cooling temperature can be selected between 0 – 40 °C 
(32 – 104 °F).

 

Fresh produce delivery system with constant regulation of load 
compartment temperature (optional feature): 
Cooling temperature can be selected between 0 – 12 °C 
(32 – 54 °F).

 

Deep frozen produce transport system: 
Cooling temperature can be selected between -20 – 40 °C 
(-4 – 104 °F).

Summary of Contents for Frigo Top 10

Page 1: ...Workshop Manual Transport Refrigeration Frigo Top 10 43 Pordoi 2000 4000 English F...

Page 2: ...vel menus 6 4 1 Entering the 1st service level 6 4 2 Entering the 2nd service level 6 4 3 Change a parameter setting 6 4 4 Exit a service menu 6 5 Set and reset the service interval 7 5 1 Enter the se...

Page 3: ...l Result damage to the refrigeration system X X Follow the operating instructions and instructions described in this document 2 Safety 2 1 General safety The repair and commissioning personnel must ha...

Page 4: ...compartment 3 3 Service levels The control element has an extensive set of parameters to regu late and control the refrigeration process The parameters are split in 2 levels Level 1 Level 2 Access th...

Page 5: ...pressor operation count appears on the display preceded by a minus sign Example If the saved value is 1511 hours of operation the first time the button is pressed 001 thousands is displayed The second...

Page 6: ...irst parameter of the 1st service level The degree symbol starts blinking 4 2 Entering the 2nd service level Fig 06 2nd level service menu Fig 07 First parameter of the 2nd level service menu X XPress...

Page 7: ...ween SEr change interval rSt reset interval 5 3 Reset the service interval Fig 14 Reset interval No Fig 15 Reset interval Yes 3 3 Make sure that the screen shows rSt ATTENTION Do not reset the service...

Page 8: ...eters from the hot key into the control element Upload parameters from the control element into the hot key Uploading parameters from the control element into the hot key provides a back up for eventu...

Page 9: ...t restarts and uses the new parameters X XRemove the hot key 6 3 Upload parameters to the hot key 3 3 Program the control element as desired with the keys on the front 3 3 Leave the control element on...

Page 10: ...ng the sensor X XContact a Webasto service partner HA Maximum temperature alarm Temperature in cooling compartment is too high LA Minimum temperature alarm Temperature in cooling compartment is too lo...

Page 11: ...input Potential free contact NTC probe 40 110 C 40 230 F Relay outputs PTC probe 50 150 C 58 302 F Compressor 8 3 A 16 6 A or 20 8 A 250 VAC Defrost 8 3 A 250 VAC Fan 8 3 250 VAC Fig 23 F 32 74 71 29...

Page 12: ...emeratures compared to the set temperature To be used in case of heating kit n neutral zone disabled cooling only y neutral zone enabled heating kit installed 2 AC Anti short cycle delay minimum inter...

Page 13: ...ant 0 99 min 2 dFd Temperature displayed during defrost rt real temperature it temperature at defrost start SEt set point dEF dEF label 2 dAd MAX display delay after defrost Sets the maximum time betw...

Page 14: ...the SET A LU or SET ALL values 2 ALU Maximum temperature alarm when this temperature is reached the alarm is enabled after the ALd delay time SET 110 C SET 230 F 2 ALL Minimum temperature alarm when...

Page 15: ...pressure switch dur ing the did interval before signalling the alarm event I2F PAL If the nPS activation in the did time is reached switch off and on the instru ment to restart normal regulation 0 15...

Page 16: ...neutral zone n n n y in case of heating kit 2 AC Anti short cycle delay 1 1 1 2 CCt Continuous cycle duration 0 0 0 2 CCS Set point for continuous cycle 0 0 0 2 COn Compressor ON time with faulty pro...

Page 17: ...2 ALd Temperature alarm delay 15 15 15 2 dAo Delay of temperature alarm at start up 1 3 1 3 1 3 2 SE Regular service has to be performed x10 hours 200 200 200 2 10 4 6 Digital input Label Description...

Page 18: ...tt oder der Webseite Ihrer jeweiligen Webasto Landesvertretung Dans le cas d une version r dig e en plusieurs langues l anglais est alors la langue qui fait foi Pour trouver le num ro de t l phone du...