10.1 Technical data
Description
Data
Description
Data
Power supply
12/24 VDC
Operating temperature
0 – 60 °C (32 – 140 °F)
Power consumption
3 VA
Storage temperature
-30-85 °C (-22 – 185 °F)
Protection
IP20
Relative humidity
20 – 80%, non-condensing
Frontal protection
IP65
Measuring and regulating
range:
Digital input
Potential free contact
NTC probe
-40 – 110 °C (-40 – 230 °F)
Relay outputs:
PTC probe
-50 – 150 °C (-58 – 302 °F)
Compressor
8(3) A, 16(6) A, or 20(8) A,
250 VAC
Defrost
8(3) A, 250 VAC
Fan
8(3), 250 VAC
Fig. 23:
F
32
74
71
29
60
Control element dimensions
10.2 (Typical) 12/24 VDC wiring and connections
Max.
16 A
1 2 3 4 5
7 8
9 10 11 12
13
Fig. 24: Wiring connections
Legenda:
1. Line
2. Defrost
3. Not connected
4. Fan
5. Compressor
6. -
7. Supply 12/24 V
8. Supply 12/24 V
9. Digital input
10. Evaporator temperature sensor
11. Common
12. Room temperature sensor