Function Description
Setting
Default
Recommended
Chiller
CPAC
AirH.
P..
Compresso
r starting
sequence
P123 = starting sequence
1,2,3,4
P341 = starting sequence
3,4,1,2 >>> etc.
P A = Automatic random
starting sequence.
Only set PA, P3** or P4** for 3
or 4 compressor units.
P123
●
L..
Start delay
each
compressor
1 - 9 seconds delay between
each compressor.
09
●
1L..
Thermostati
c advance
comp. 1
1L1.0 = 4˚C + 1˚C = 5˚C
switching off comp. 1
0.0
●
2L..
Thermostati
c advance
comp. 2
2L2.4 = 4˚C + 2.4˚C = 6.4˚C
switching off comp. 2
0.0
●
3L..
Thermostati
c advance
comp. 3
3L3.1 = 4˚C + 3.1˚C = 7.1˚C
switching off comp. 3
0.0
●
4L..
Thermostati
c advance
comp. 4
4L0.0 = 4˚C + 0˚C = 4˚C
switching off comp. 4
0.0
●
d…
Automatic
dehumidifyi
ng when
unit is
switched off
(1).
0 = not active
1 = 1x in 24h
2 = 2x in 24h
3 = 3x in 24h
00
●
●
●
(1) To synchronize clock air-handler and chiller controller, cut-off the
main supply after setting a dehumidifying cycle and controllers are
shut-off.
See also settings c and d in 15˚C menu. Don’t set d1-d3 when
onboard or it will wake you up at the oddest hours.
t…
Display
time
secondary
functions
before
room
temperatur
e is shown
again.
01 -05 (1
period is 20
seconds)
01
●
●
●
29˚C Menu
Code
Description
Possible
Default
Recommended
Chiller
CPAC AirH.
0
T cut-out in cool cycle.
(de-icing starting) See
also 1L00.
Min. 00 / Max.14 ˚C
04 Chiller
00 CPAC
●
●
1
T cut-in in cool cycle.
Min. 00 / Max.14 ˚C
07 Chiller
05 CPAC
●
●
Summary of Contents for Azimut 43 Fly