Operation manual Soldos - SL (04-09) page 4 of 18
1. Application
The Soldos-SL nebulises brine solution for dry rooms by the use of a two-
component jet nozzle (compressed air and brine solution). After a short
time a salty sea climate is created in the room.
Due to the variety of setting parameters it is easy to adopt the SOLDOS-
SL to the site of operation. The dosing capacity depends also on the room
climate (humidity, temperature) and the air circulation rate. In general
useable for rooms with a floor space of app. 35m².
1.1 Function
The brine solution is primed out of an air sealed bag (Politainer) by a
peristaltic pump. This bag interfolds itself when the liquid brine solution is
taken out. This procedure prevents the contamination of brine solution
with germs of the ambient air. The peristaltic pump conveys the brine
solution to the two-component jet nozzle where it is nebulised and blown
into the room by the addition of compressed air.
The compressed air for the nebulisation has a follow-up time of 10 seconds
to prevent encrustation at the nozzle and follow-up dripping at the nozzle.
If the brine bag gets empty the nebulisation stops and the green-LED
blinks. An electrical output for a malfunction message can be connected.
The empty report is realized by an empty switch.
1.2 Option: additional functions
The controller of the SOLDOS-SL gives also the possibility to equip the unit
with additional attractions such as light and sound effects (MP3 sound
module). These attractions can be switched-on in parallel to the
nebulisation of the brine solution. This offers the possibility to create
ambience together with the salt infusion.