Dosing unit GRANUDOS Type Flex-CPR Touch XL,
Type Flex-Touch and Type Flex-S5
Index: 01 Change date: 11/10/2023
OI No.: BA SW 022-01 Granudos Flex Dosiereinheit EN.docx
Page 41 of 68
5.2.4
Filling the dosing hopper with chlorine granulate
WARNING!
The chlorine granulate and acid must not be mixed with each other or with other chemicals
or substances! These substances can have a strong reaction when combined with each other
and release toxic chlorine gas outside of water.
Remove potential encrustations from the dosing hopper to prevent faults during the chlo-
rine dosing.
Personal safety equipment must be put on before starting work with chemicals: Protective
gloves, apron, face protection, foot protection.
Pay attention to the safety data sheets for each chemical.
5.2.4.1
Filling without filling appliance
Procedure
a)
Remove the cover. Using a cup, carefully empty the chlorine granulate into the dosing hopper
along the wall so that no chlorine dust is produced (do not dump it in!).
b)
Then close the cover
Only fill in the amount needed for about 1-2 weeks so that the chlorine granulate does not bond
with the humidity in the air, clump together and trickle down less easily.