Dosing unit GRANUDOS Type Flex-CPR Touch XL,
Type Flex-Touch and Type Flex-S5
Index: 01 Change date: 11/10/2023
OI No.: BA SW 022-01 Granudos Flex Dosiereinheit EN.docx
Page 28 of 68
4.3
Mechanical installation
The GRANUDOS is delivered completely pre-assembled, including the control unit, the dirt filter and
the collecting tub (option), and is thus ready for installation.
4.3.1
GRANUDOS Flex installation
Procedure
a)
Unpack the GRANUDOS and set it up and align it on a suitable, level foundation in the technical
room.
b)
Proceed in the same way with the dosing canisters, the buffer tank (option) and the corresponding
collecting tubs.
c)
Ensure that there is sufficient clearance for operating and servicing the device!
4.3.2
Buffer tank installation
The buffer tank may only be operated with a suitable collecting tub. (Possibly a collecting tub provided
On-site.)
Procedure
a)
Place and align the collecting tub on a suitable, level foundation in the technical room.
b)
Place the empty buffer tank in the collecting tub and check for secure footing.
c)
Ensure that there is sufficient clearance for operating and servicing the device.
4.4
Hydraulic installation
NOTICE!
When using Captura swimming pool filters, an automatic vent must be installed in the swimming
pool water cycle. Otherwise, fault may occur in the GRANUDOS system. For more detailed coordina-
tion, please contact WDT.
Installation materials
Spare parts bag with manometer and hole washers with 5.5 and 7 mm drill
hole
Accessories for acid pump
Accessories for flocculant pump (option)
Dosing valve type 1Sk (option)