GRANUDOS Touch, control unit
Index: 02
Date modified: 11/06/2019
OI No.: BA SW 010-02 Granudos Touch-Steuereinheit EN SCHW 8.docx
Page 8 of 43
3.3
Identification of device / nameplate
For spare part orders and troubleshooting, it is useful to know the device serial number and the firmware version. The
device serial number is located on the nameplate on the right side of the control casing. The firmware version can be
found using the menu item
Menu
Service
Info
.
Nameplate see OI Part 1 for the dosing devices
for Granudos 10-Touch,
No.: BA SW 002
for Granudos 45/100-Touch, No.: BA SW 003
3.4
Technical data
GRANUDOS 45/100 Touch Control
Unit
GRANUDOS 10 Touch Control Unit
Connection data
Electric connection data
230VAC/50Hz ± 10%, 35W, I max.
0.2A, standby 22VA, safety (Schuko)
plug
230VAC/50Hz ± 10 %, 35W, I max.
0.2A, standby 22VA, safety (Schuko)
plug
Protection class
Casing IP54
Casing IP54
Interface connection
Modbus TCP, USB for data export
Modbus TCP, USB for data export
Operating data:
Measuring range
pH value: 2.00 to 12.00
pH value: 2.00 to 12.00
Medium temperature
Ambient temperature
Humidity engineering room
0°C to 40°C
5°C to 35°C
max. 80% non-condensing
0°C to 40°C
5°C to 35°C
max. 80% non-condensing
Concentration hypochlorous acid max. 0.4%
max. 0.2%
Room ventilation (in and out)
According to DIN 19643
According to DIN 19643
Material
Casing: PS
Casing: PS
Firmware version
---
---
Hardware version
---
---
3.5
Transport / storage
Please check the devices immediately upon receipt for potential transport damage.
ATTENTION!
The systems and devices can be damaged by frost or high temperatures. Avoid
exposure to frost during transport and storage! Do not store systems and devices
next to objects with strong heat emission or in direct sunlight. The device may only
be transported and stored in its original packaging. Please ensure careful handling.