WCC PS-5 Series Manual Download Page 8

8

7150 143rd Avenue NW

Ramsey, MN 55303

Tel: (763) 427-9638

Toll Free: (866) 405-1268

www.watercontrolinc.com

Manufactured by:

W

ater

C

ontrol

C

orporation

System Activation and Flushing

7150 143rd Avenue NW

Ramsey, MN 55303

Tel: (763) 427-9638

Toll Free: (866) 405-1268

www.watercontrolinc.com

Manufactured by:

W

ater

C

ontrol

C

orporation

System Activation  and Inspection 

1. Check all tubing connections to ensure they are firmly seated.  CHECK TO SEE THAT THE CARTRIDGE RETAINER CLIP IS

PROPERLY ENGAGED AND LOCKED. Failure to keep the retaining clip in place will result in accidental leaks and flooding. 

2. Open the dispensing faucet at the sink.  Close the tank shut-off valve. Make sure the angle stop valve for the incoming

water is open. Open the small feed shut-off valve on feed valve assembly.

3. Observe all tubing and connections for several minutes to detect any leaks.  In approximately 5 minutes, (assuming

normal feed water pressure) the dispensing faucet should begin dripping.

4. Allow the faucet to run for up to 15 minutes, then close the faucet.

5. Check for leaks at all connections.

6. Open the tank shut-off valve.

Initial Flushing Procedure

1. Before the system can be used for drinking water production it must be adequately flushed.  Each reservoir tank is

dosed with a small amount of powdered sanitizer before shipment, typically a chlorinating agent, in order to ensure tank

internal cleanliness.  Also, the carbon filter cartridge will release a small amount of carbon fines during the first tankful of

flow.  This flushing procedure will allow any sanitizer or carbon fines to pass from the system.

2. Initial tank filling will take approximately one hour (based on average feed pressure).  When the tank is full, the water

pressure will have risen to the point where the automatic shut-off valve inside the system will stop the feed flow through

the system.  Actuation of the automatic shut-off valve can be determined by either checking for a lack of brine flow to the

drain saddle, or by listening very closely near the dispensing faucet for absence of water flow sound though the air gap.

When the tank has filled for the first time, it should be left undisturbed for at least 8 hours to ensure proper sanitization.

3. After 8 hours has elapsed, open the dispensing faucet fully and allow the product water to run out to drain at maximum

flow.  The initial discharge will be dark with the bulk of the carbon particle wash out.  There may also be the scent of chlo

-

rinated water from the sanitizing agent.  When the flow has diminished to a fast drip or small stream, close the dispensing

faucet.

4. Fill and flush the tank at least three times prior to use.  If necessary, repeat until the chlorination scent has disappeared.

It is important that the flush be done at maximum flow (e.g. the tank must be full) to assist in rapid wash out.  After this
flushing procedure the system is ready for normal use.

Water Control Corporation
7150 143rd Ave NW  Ramsey, MN 55303

 

Phone: 866-405-1268  Fax: 763-427-5665

 

www.watercontrolinc.com
© Water Control Corporation 0820

Summary of Contents for PS-5 Series

Page 1: ...oll Free 866 405 1268 Manufactured by Water Control Corporation PS 5 Series 5 Stage Reverse Osmosis System Water Control Corporation 7150 143rd Ave NW Ramsey MN 55303 Phone 866 405 1268 Fax 763 427 56...

Page 2: ...r PS 5 Please fill out the following information at the time of installation Save for future reference 7150 143rd Avenue NW Ramsey MN 55303 Tel 763 427 9638 Toll Free 866 405 1268 www watercontrolinc...

Page 3: ...information on the proper care and maintenance of your system please take a few minutes to read through this information The cartridges in this system must be replaced on a regular basis to maintain e...

Page 4: ...nufacturer assumes no liability for the determination of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Wa...

Page 5: ...tubing 3 8 white G Quick connect fitting H Drain tubing 1 4 black I Faucet tubing 3 8 blue J Four stage desalinator K Feed water tubing 1 4 green L Feed valve assembly with adapter and shut off valve...

Page 6: ...e 3 8 white tubing onto the larger 3 8 fitting located on the faucet base 7 Slide white plastic spacer open end up onto the threaded faucet stem 2 Note This spacer may be omitted it faucet is installe...

Page 7: ...hex nuts and the small adhesive foam pad from the small parts bag Fig 2 3 Place the adhesive foam pad on the inside of the the drain saddle front aligning the holes 4 Position the drain saddle on the...

Page 8: ...release a small amount of carbon fines during the first tankful of flow This flushing procedure will allow any sanitizer or carbon fines to pass from the system 2 Initial tank filling will take approx...

Page 9: ...ress top or bottom of cartridge to engage connectors until it snaps into place properly 4 All tubing connections especially push in quick connections are fully inserted 5 Tubing connected between the...

Page 10: ...the retaining clip will result in accidental leaks and flooding 7 Open the small shut off valve on the feed valve assembly Open the dispensing faucet 8 Close dispensing faucet after water starts runni...

Page 11: ...303 Tel 763 427 9638 Toll Free 866 405 1268 Manufactured by Water Control Corporation Water Control Corporation 7150 143rd Ave NW Ramsey MN 55303 Phone 866 405 1268 Fax 763 427 5665 www watercontrolin...

Reviews: