This system has been designed for installation by a licensed professional such as a contractor or plumber. Proper completion of this installa
-
tion will require basic familiarity with standard sink plumbing and proper use of common hand and power tools. Improperly installed systems
could result in water damage due to leaks or flooding.
System - 9.75” W x 13.5” D x 15.5” H ( 24.8 x 34.3 x 39.4 cm), 11 lbs. (5 kg.)
Shipping Box - 14.5"L x 11.25"W x 20"H (36.8 x 28.6 x 50.8 cm), 13.7 lbs. (6.2 kg.)
Dimensions and Weight
A. Product water storage tank
B. Tank valve
C. Tank tubing (3/8” white)
D. Air-gap faucet
E. Drain connection assembly
F. Drain tubing (3/8” white)
G. Quick connect fitting
H. Drain tubing (1/4” black)
I. Faucet tubing (3/8” blue)
J. Four-stage desalinator
K. Feed water tubing (1/4” green)
L. Feed valve assembly (with adapter
and shut-off valve).
M. Carbon post-filter
A
B
J
E
F
G
D
K
L
M
I
H
C
(not shown)
(behind cover)
Pressure
40-80 psi (275 kPa - 552 kPa)
Temp
40°F - 100°F (4°C - 38°C)
TDS
<2000 mg/L
Chlorine
<1.0 mg/L
Turbidity
<1 NTU
SDI
<5
pH
4-8
Performance Specifications
Feed water must be potable, municipal water. Must
be free of potential membrane foulants such as Iron,
Hydrogen Sulfide and Manganese.
Membrane Production
50 GPD
System
Production
14.61GPD
TDS Rejection
96.5%
Recovery
1
26.76%
System tested at 50 psig, 750ppm TDS at 77°F.
1
The percentage of the feed water available
as reverse osmosis treated water under
normal operating conditions.
Feed Water Requirements
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.