Feed and Drain Connections

7150 143rd Avenue NW

Ramsey, MN 55303

Tel: (763) 427-9638

Toll Free: (866) 405-1268

www.watercontrolinc.com

Manufactured by:

W

ater

C

ontrol

C

orporation

Feed Connection

1. Locate and turn off the angle stop valve on the cold water line feeding the sink.  This valve will

usually be located under the sink on the pipe coming out of the wall. 

2. When the angle stop valve is closed, relieve pressure in the line by momentarily opening the

cold water tap on the sink.

3. Disconnect the cold water faucet feed line at the angle stop valve.

4. Install the feed valve assembly into the angle stop. (Fig. 1)

5. Firmly press the green 1/4” tubing into the 1/4" connector on the feed valve assembly.

6. Connect the cold water faucet feed line into the feed valve assembly.

7. Make sure the small shut-off valve on the feed valve assembly is closed.  Turn on the feed water

connection valve.  Check for leaks.

7. Attach the small feed valve warning tag from the parts bag to the feed valve.

8. Attach the Shutoff Warning label to the system so that it is directly visible. Fill out the Date of

Installation label and attach to the side of the system.

Drain Connection

1. You will need an electric drill with a 3/8” bit and a screwdriver for this portion of the installa

-

tion.

2. Obtain the drain saddle assembly, two 1 ½” bolts, two 3/8” hex nuts, and the small adhesive

foam pad from the small parts bag (Fig. 2).

3. Place the adhesive foam pad on the inside of the the drain saddle front, aligning the holes.

4. Position the drain saddle on the drain pipe under the sink between the “P” trap and the sink

connection.  Orient the drain saddle so that the opening is on the side of the drain pipe.

5. Using the bolts and hex nuts, hand tighten the saddle bracket evenly until the saddle grips the

pipe snugly.  Use a Phillips screwdriver to fully tighten the bolts.   Do not overtighten.

6. If necessary, remove the drain saddle connector nut from the opening of the drain saddle.

Using the connector opening in  the side of the drain saddle as a guide, drill a 3/8" hole through

the wall of the drain pipe.

7. Extend the drain tubing from the RO dispensing faucet to the drain saddle and measure for

length.  The tubing must be routed so that water can run downhill for the entire length of the

tubing from the faucet.  Avoid low spots or loops.  Cut the tubing shorter, if necessary.

8. Insert the drain tube from the R.O. dispensing faucet through the drain saddle connector nut.

Tighten the connector nut onto the drain saddle.

Fig. 2

Note: The drain saddle 

assembly must be 

installed before the 'P' 

trap.  Do not install the 

drain saddle assembly 

between the 'P' trap 

and the wall. 

Adapter

Shut-off valve

Fig. 1

Note: The feed valve 

adapter may be  

configured to fit either 

a 3/8" or 1/2" angle 

stop connection by 

changing the location 

of the adapter.

Angle stop

Water Control Corporation
7150 143rd Ave NW  Ramsey, MN 55303

 

Phone: 866-405-1268  Fax: 763-427-5665

 

www.watercontrolinc.com
© Water Control Corporation 0820

Summary of Contents for PS-5 Series

Page 1: ...oll Free 866 405 1268 Manufactured by Water Control Corporation PS 5 Series 5 Stage Reverse Osmosis System Water Control Corporation 7150 143rd Ave NW Ramsey MN 55303 Phone 866 405 1268 Fax 763 427 56...

Page 2: ...r PS 5 Please fill out the following information at the time of installation Save for future reference 7150 143rd Avenue NW Ramsey MN 55303 Tel 763 427 9638 Toll Free 866 405 1268 www watercontrolinc...

Page 3: ...information on the proper care and maintenance of your system please take a few minutes to read through this information The cartridges in this system must be replaced on a regular basis to maintain e...

Page 4: ...nufacturer assumes no liability for the determination of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Wa...

Page 5: ...tubing 3 8 white G Quick connect fitting H Drain tubing 1 4 black I Faucet tubing 3 8 blue J Four stage desalinator K Feed water tubing 1 4 green L Feed valve assembly with adapter and shut off valve...

Page 6: ...e 3 8 white tubing onto the larger 3 8 fitting located on the faucet base 7 Slide white plastic spacer open end up onto the threaded faucet stem 2 Note This spacer may be omitted it faucet is installe...

Page 7: ...hex nuts and the small adhesive foam pad from the small parts bag Fig 2 3 Place the adhesive foam pad on the inside of the the drain saddle front aligning the holes 4 Position the drain saddle on the...

Page 8: ...release a small amount of carbon fines during the first tankful of flow This flushing procedure will allow any sanitizer or carbon fines to pass from the system 2 Initial tank filling will take approx...

Page 9: ...ress top or bottom of cartridge to engage connectors until it snaps into place properly 4 All tubing connections especially push in quick connections are fully inserted 5 Tubing connected between the...

Page 10: ...the retaining clip will result in accidental leaks and flooding 7 Open the small shut off valve on the feed valve assembly Open the dispensing faucet 8 Close dispensing faucet after water starts runni...

Page 11: ...303 Tel 763 427 9638 Toll Free 866 405 1268 Manufactured by Water Control Corporation Water Control Corporation 7150 143rd Ave NW Ramsey MN 55303 Phone 866 405 1268 Fax 763 427 5665 www watercontrolin...

Reviews: