WCC PS-5 Series Manual Download Page 4

4

7150 143rd Avenue NW

Ramsey, MN 55303

Tel: (763) 427-9638

Toll Free: (866) 405-1268

www.watercontrolinc.com

Manufactured by:

W

ater

C

ontrol

C

orporation

Warranty

7150 143rd Avenue NW

Ramsey, MN 55303

Tel: (763) 427-9638

Toll Free: (866) 405-1268

www.watercontrolinc.com

Manufactured by:

W

ater

C

ontrol

C

orporation

This Limited Warranty extends to the original purchaser of the system only. This warranty covers all Manufacturer-supplied items only that 

prove to be defective in material, workmanship or factory preparation. This warranty covers parts only; all labor is excluded from this war

-

ranty, including, but not limited to, services related to the removal, replacement, installation, adjustment, maintenance and/or repair of 

the unit or its components items. excludes all non-Manufacturer labor required for any servicing of the unit, including, but not limited to, 

servicing related to installation, adjustment, maintenance and repair of the unit. This warranty applies only for the first full calendar year 

from date of purchase. The following items are excluded from this warranty: membranes, filters, O-rings, and all other parts or compo

-

nents that require regular replacement as a result of ordinary usage.  

Disclaimers

: This Limited Warranty applies only if the system is installed, used and maintained in compliance with all instructions and 

requirements enclosed with the system. This warranty will be void for failure to observe the following conditions: 

1. The system is to be used with potable water from a municipal water system.

2. Feed water pressure to the unit is no less than 40 PSI and no greater than 80 PSI.

3. The system is to be used on water supplies with chlorine concentrations of 1.0 mg/L (ppm) or less.

4. Feed water temperature to the unit must be no less than 40°F and no more than 100°F.

5. Total dissolved solids in feed water must be less than 2,000 mg/L (ppm).

6. Feed water must have a pH between 4 and 8.

7. Turbidity must be less than 1.0 NTU.

8. SDI must be less than 5.

9. Feed water must be completely free of iron, manganese or hydrogen sulfide.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

The Manufacturer does not know the characteristics of your water supply. The quality of water supplies may vary seasonably or over a  

period of time. Your water usage may vary as well. Water characteristics can also change if the drinking water appliance is moved to a new 

location. The Manufacturer assumes no liability for the determination of the proper equipment necessary to meet your requirements, and 

we do not authorize others to assume such obligation on our behalf. 

This Limited Warranty does not cover any Manufacturer-supplied items that are defective as a result of the use of improper parts, equip

-

ment or materials. This warranty does not cover alterations or modifications of the unit, or failure of a unit caused by such alterations and 

modifications 

This Limited Warranty does not cover malfunctions of the unit due to tampering, misuse, alteration, lack of regular maintenance, misap

-

plication, fouling due to hydrogen sulfide, manganese or iron, scaling from excessive hardness, turbidity greater than 1.0 NTU, Silt Density 

Index (SDI) greater than 5.0 SDI, or excessive membrane hydrolysis due to chlorine levels in excess of 1.0 mg/L (ppm).  In addition, damage 

to the unit due to fire, accident, negligence, act of God, or events beyond the control of the Manufacturer are not covered by this war

-

ranty. 

Incidental and Consequential Damages Limitation

: The Manufacturer will not be responsible for any incidental or consequential damages 

as a result of the failure of this unit to comply with express or implied warranties or any defect in the unit, including but not limited to, lost 

time, inconvenience, damage to personal property, loss of revenue, commercial losses, postage, travel, telephone expenditures, or other 

losses of this nature. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this exclusion may 

not apply to you.

Owner’s Warranty Responsibilities

: As a condition of this Limited Warranty, the owner must ensure periodic maintenance of the system 

is performed as described in the literature enclosed with the system. Neglect, improper maintenance, abuse, modification or alteration of 

the unit will invalidate this Warranty.  Should your unit develop a defect or otherwise fail to perform in accordance with this warranty, you 

should contact the retailer from whom the product was originally purchased.

Implied Warranties

: The implied at-law warranties of merchantability and fitness for a particular purpose shall terminate on the date one 

year after the date of purchase. Note: some states do not allow limitations on how long an implied warranty lasts, so the above limitations 

may not apply to you.

Other Rights: 

This Warranty gives you specific legal rights and you may also have other rights which vary from state to state.

Water Control Corporation
7150 143rd Ave NW  Ramsey, MN 55303

 

Phone: 866-405-1268  Fax: 763-427-5665

 

www.watercontrolinc.com
© Water Control Corporation 0820

Summary of Contents for PS-5 Series

Page 1: ...oll Free 866 405 1268 Manufactured by Water Control Corporation PS 5 Series 5 Stage Reverse Osmosis System Water Control Corporation 7150 143rd Ave NW Ramsey MN 55303 Phone 866 405 1268 Fax 763 427 56...

Page 2: ...r PS 5 Please fill out the following information at the time of installation Save for future reference 7150 143rd Avenue NW Ramsey MN 55303 Tel 763 427 9638 Toll Free 866 405 1268 www watercontrolinc...

Page 3: ...information on the proper care and maintenance of your system please take a few minutes to read through this information The cartridges in this system must be replaced on a regular basis to maintain e...

Page 4: ...nufacturer assumes no liability for the determination of the proper equipment necessary to meet your requirements and we do not authorize others to assume such obligation on our behalf This Limited Wa...

Page 5: ...tubing 3 8 white G Quick connect fitting H Drain tubing 1 4 black I Faucet tubing 3 8 blue J Four stage desalinator K Feed water tubing 1 4 green L Feed valve assembly with adapter and shut off valve...

Page 6: ...e 3 8 white tubing onto the larger 3 8 fitting located on the faucet base 7 Slide white plastic spacer open end up onto the threaded faucet stem 2 Note This spacer may be omitted it faucet is installe...

Page 7: ...hex nuts and the small adhesive foam pad from the small parts bag Fig 2 3 Place the adhesive foam pad on the inside of the the drain saddle front aligning the holes 4 Position the drain saddle on the...

Page 8: ...release a small amount of carbon fines during the first tankful of flow This flushing procedure will allow any sanitizer or carbon fines to pass from the system 2 Initial tank filling will take approx...

Page 9: ...ress top or bottom of cartridge to engage connectors until it snaps into place properly 4 All tubing connections especially push in quick connections are fully inserted 5 Tubing connected between the...

Page 10: ...the retaining clip will result in accidental leaks and flooding 7 Open the small shut off valve on the feed valve assembly Open the dispensing faucet 8 Close dispensing faucet after water starts runni...

Page 11: ...303 Tel 763 427 9638 Toll Free 866 405 1268 Manufactured by Water Control Corporation Water Control Corporation 7150 143rd Ave NW Ramsey MN 55303 Phone 866 405 1268 Fax 763 427 5665 www watercontrolin...

Reviews: