background image

     the System tallies and remembers the number of rings.
2.  On your second call within “3” minutes, let the phone ring 

     until the System answers. The System will answer 

     first because it remembered the first “3” rings, and then 

     answers with an audible system status.  If done properly, the 

     answering machine/voice mail will not answer.  

HOW TO CANCEL ALARM PHONE CALLS FROM YOUR 

SYSTEM

To cancel the alarm phone call from one of the numbers in the 

phone call list:
To cancel a call out sequence from the System while listening to 

an alarm message, do the following:
1.  Answer the phone call.
2.  Listen to the alarm message.
3.  When told, press the number “1” key followed by the 

     pound (#) key within “1” minute to cancel the alarm call 

     out. You can cancel the call at anytime during the 

     message.  
4.  You can listen until you hear the System say goodbye 

     or just hang up the phone.
5.  If you do not cancel the call, the system will call the next 

     number in your phone number list. The first cancel will 

     stop all calls for all numbers. This sequence will repeat 

     every 15 minutes until a call is cancelled.  
To cancel the alarm phone call using the System display:
Press and hold the RESET button once to cancel the call (phone 

icon is present) and the RESET up to 5 seconds if multiple 

errors/alarms are present on the display to stop receiving phone 

calls. You will then be required to also clear/reset the message(s) 

on the display.  
 

 

PLACE A PHONE CALL TO YOUR SYSTEM TO CANCEL AN 

ALARM

To cancel a call out sequence during an active alarm condition, 

do the following:
1.  Make the call to the System (phone number at alarm 

     location)
2.  Wait for the System to answer (5 or 10 rings Menu option 

     selectable)
3.  Listen to the alarm message.
4.  Press the number “1” key followed by the pound (#) key 

     anytime during the message to cancel the alarm call out 

     and then hang up the phone.

REMOTE STATUS CHECK 

The System will answer incoming calls if a warning condition 

exists on the display. When no alarm issue exists, you will get 

a general status update.  If the call out sequence has been 

cancelled for an alarm by pressing "1" then "#" on the phone, 

but the alarm condition still exists on the display, the System will 

answer and describe the alarm condition.

7

CANCELING AN ALARM CALL OUT SEQUENCE WITH AN 

ANSWERING MACHINE/VOICE MAIL DEVICE ON THE SAME 

PHONE LINE

To cancel the alarm call out-sequence, do the following:

STEP ACTION

1.  Make the call to the System (phone number at alarm 

     location).
2.  Let the phone ring the desired number of times (before the 

     other in-line answering machine/voice mail can answer), Hang 

     the phone up.
3.  Call the number a second time within three minutes (The 

     System keeps track of all the rings from the previous 

     calls, accumulates them until the total ring count matches its 

     ring count number, 5 or 10, and then it will answer). Listen to 

     the alarm message.
4.  Press the number “1” key followed by the pound (#) key 

     anytime during the message to cancel the alarm call out. Hang 

     up the phone.

OPERATION

1.  After installation, the back-up pump will start once the water 

     level raises the bottom float.  

2.  The System has a charging circuitry designed to optimize the 

     recharging time of your battery and to prevent overcharging. 

     In addition, the control box has a time delay which keeps the 

     pump from repeated, short cycles when it shuts off. This 

     time delay feature will allow the pump to run 15 seconds 

     after the switch reaches the off position.

3.  MUTE FUNCTION: Press the mute button once to silence the 

     alarm for 12, 24, or 48 hours (menu selectable). To turn off the 

     mute timer, press and hold the RESET button down for 5  

     seconds.

1.  Unplug the transformer.

2.  For batteries with top caps that can be removed, the 

     electrolyte level should be checked and filled to 

     manufacturer’s specifications. The charge for each cell 

     should be checked with a hydrometer. A specific gravity of 

     1.265 indicates the battery is at full charge. If the specific 

     gravity of any of the cells varies more than .050, the battery 

     should be replaced.
3.  If the battery fluid levels are low or battery plates are exposed, 

     refer to the manufacturer's recommendations on how to 

     replenish properly.
4.  Inspect the terminals and clamps for corrosion and 

     tightness. Clean and tighten as required.

EXTENSION CORDS

We DO NOT recommend using extension cords, but if you find it 

absolutely necessary then:
1.  Use at least a 16 gauge cord that does not exceed 50 feet 

     in length.

 

Explosion hazard. Smoking  

 

 

 

and open flames prohibited. 

Battery recharging and connections MUST be performed 

in a well ventilated area. Before servicing the batteries, 

blow away the gases by waving a piece of cardboard near 

the batteries. 

BATTERY CARE AND MAINTENANCE

Operating Instructions and Parts Manual

WSM3300

 

If the System is set to answer in 10 rings (one of 

 

the Menu selectable options), you will need to 

place more calls within "3" minutes to get the System to eventually answer.

 

Canceling the call out sequence does not 

 

cancel an active alarm. System will continue 

to beep and the alarm message will be displayed on the digital display 

until you hit reset for each message/condition. If you do not hit reset, each 

alarm message on the display system will recall the phone number(s) in 

the last 72 hours as a reminder for the uncleared alarm conditions. 

 

An inexpensive hydrometer can be purchased at 

 

an automotive parts dealer.

www.waynepumps.com

Summary of Contents for WSM3300

Page 1: ...able Batteries Transformer Wear safety glasses when connecting the battery STEP 5 CONNECT LID TO BATTERY Transformer 1 Lid and Controller Assembly 1 Battery box 1 12 Volt DC back up pump 1 Switch with...

Page 2: ...to equipment GENERAL SAFETY INFORMATION This pump is NOT rated for use with flammable combustible liquids vapors or dusts Do NOT use to pump flammable combustible liquids vapors or dusts Do NOT use i...

Page 3: ...separately to the top of the discharge pipe This will allow the pump or check valve to be removed easily for servicing 8 Check valve is recommended for effective operation of system The remainder of...

Page 4: ...pipe is required for permanent installation 9 Glue a 45 elbow to the short pipe on the Back Up DC Pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method 2 10...

Page 5: ...negative terminal of the battery The display should be lit up at this time If connected improperly an alarm will sound until corrected 4 Plug the pump and float switch connectors into the 12 Volt Adva...

Page 6: ...d phone number hit ENTER then select the TEST option The system will immediately dial the desired phone number Upon answering the unit will play the following message This is a test of the back up sys...

Page 7: ...up 3 Call the number a second time within three minutes The System keeps track of all the rings from the previous calls accumulates them until the total ring count matches its ring count number 5 or...

Page 8: ...E NUMBER REN The REN is used to determine the number of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices not ringing in response to an in...

Page 9: ...efective 5 Check to make sure the back up pump is not air locked Locate the vent hole inspect and clear the hole using a pipe cleaner Pump Cycles Too Frequently 1 Check valve problem 1 Check to make s...

Page 10: ...R PUR POSE ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE THIS IS THE EXCLUSIVE REM E DY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAM AG ES OR EXPENSES WHATSOEVER IS EXCLUDED Som...

Page 11: ...l set to 4 rings the System set to 5 rings 1 Make a phone call to the System phone number at alarm location let ring three 3 times hang up 2 Make a second call to the System within 3 minutes the Syste...

Page 12: ...tr leur termin e r tablir l alimentation c a et v rifier la pompe principale conform ment la description donn e dans la section Fonctionnement de ce manuel Rouge Noir N inclut pas la batterie d charge...

Reviews: