METHOD 2 - See Figure 2

If a separate, dedicated discharge is not possible as in Method 

1, the Back-Up DC Pump can be tied into the AC-operated 

pump’s discharge pipe by installing a “Y” or "T" connector. 

Two check valves will be required.

1.    Locate the Back-Up DC Pump on a solid, level surface in the 

  sump pit. Do not place the pump on a loose or sandy surface. 

  Small stones or sand may damage the pump resulting in 

  pump failure.

2.   This pump has a 1-1/2 in. NPT discharge. If a 1-1/4 in. 

  discharge pipe is desired, an adapter (sold separately, part 

  #66002-WYN1 WAYNE adapter or equivalent) will be 

  necessary. Smaller diameter piping will reduce pump  

  flow-rate and performance.

3.   A check valve will be required in the discharge line of both 

  the Main AC pump and the Back-Up DC pump to prevent    

  recirculation of water into the sump pit. System will not  

  function without two check valves.

4.   Cut a 4 ft. section of 1-1/4 in. or 1-1/2 in. diameter rigid PVC 

  pipe. Cement 1-1/2 in. pipe to a threaded fitting. Cement 

  1-1/4 in. pipe into pipe coupling. Attach 1-1/4 in. pipe 

  section to the Back-Up DC Pump discharge adapter.

5.  Screw into pump discharge.
6.  Place the pump with the 4 ft. section of PVC pipe on the 

sump floor or on an elevated surface if required.

7.  Attach a rubber check valve (sold separately) to the top of 

the discharge pipe. This will allow the pump or check valve 

to be removed easily for servicing.

8.  Duplicate the discharge piping arrangement for the primary 

AC pump if the existing discharge line has to be adjusted to 

accommodate a second pump.

Figure 1 - Method 1 (Preferred Installation)

 

Do NOT strip or cross thread plastic  

 

fittings or check valves. Flex hose is NOT 

recommended. Rigid PVC or metal pipe is required for permanent installation.

9.  Glue a 45º elbow to the short pipe on the Back-Up DC 

Pump. Glue a “Y” adapter to the short pipe on the existing 

pump, as shown in illustration for Method 2.

10. Glue a short piece of PVC pipe between the 45º elbow and the 

“Y”.

The remainder of the discharge pipe installation will vary 

depending on individual circumstances. Using sound plumbing 

practices, route the discharge pipe to an exterior wall by the 

shortest distance.

METHODS 1 AND 2

Install float switch at least 10 in. -12 in. above bottom of sump 

pit so that back-up unit turns on only when the water level is 

higher than the normal “on” level for main pump. Make sure 

power wires and hose clamp ends do not interfere with float 

switch, pump inlet, or main pump operation. The back-up 

pump must not be allowed to run dry except during the 20 

second "auto-test. Incoming water can not flow directly onto 

the float switch. Failure to position properly may cause improper 

operation. Position the float switch so that it will not interfere 

with any portion of the plumbing, wiring, or sump pit. Check for 

clearance by lifting both floats.    

Figure 2 - Method 2 (Alternate Installation)

Floor Joist

Rigid  

PVC  

Pipe

Transformer

Check Valve

Check Valve

Primary Pump

Back-Up DC Pump

1-1/4 in.  

or  

1-1/2 in.  

PVC Pipe

Slope Pipe Down

Floor Joist

Rigid  

PVC  

Pipe

Transformer

Check Valve

Check Valve

Primary Pump

1-1/4 in.  

or  

1-1/2 in. 

PVC Pipe

Slope Pipe Down

Phone Jack

Phone Jack

12 Volt 

Advanced 

Notification 

System

12 Volt 

Advanced 

Notification 

System

Back-Up DC Pump

Operating Instructions and Parts Manual

Figure 3 - 12 Volt Advanced Notification System elevated

Zip Tie

Zip Tie

Zip Tie

Zip Tie

 

Check valves MUST be installed in the 

 

discharge line of both the main AC pump and 

the back-up DC pump. Failure to install the check valves MAY allow 

water to recirculate into the sump pit. See Figures 1 and 2.

www.waynepumps.com

Summary of Contents for WSM3300

Page 1: ...able Batteries Transformer Wear safety glasses when connecting the battery STEP 5 CONNECT LID TO BATTERY Transformer 1 Lid and Controller Assembly 1 Battery box 1 12 Volt DC back up pump 1 Switch with...

Page 2: ...to equipment GENERAL SAFETY INFORMATION This pump is NOT rated for use with flammable combustible liquids vapors or dusts Do NOT use to pump flammable combustible liquids vapors or dusts Do NOT use i...

Page 3: ...separately to the top of the discharge pipe This will allow the pump or check valve to be removed easily for servicing 8 Check valve is recommended for effective operation of system The remainder of...

Page 4: ...pipe is required for permanent installation 9 Glue a 45 elbow to the short pipe on the Back Up DC Pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method 2 10...

Page 5: ...negative terminal of the battery The display should be lit up at this time If connected improperly an alarm will sound until corrected 4 Plug the pump and float switch connectors into the 12 Volt Adva...

Page 6: ...d phone number hit ENTER then select the TEST option The system will immediately dial the desired phone number Upon answering the unit will play the following message This is a test of the back up sys...

Page 7: ...up 3 Call the number a second time within three minutes The System keeps track of all the rings from the previous calls accumulates them until the total ring count matches its ring count number 5 or...

Page 8: ...E NUMBER REN The REN is used to determine the number of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices not ringing in response to an in...

Page 9: ...efective 5 Check to make sure the back up pump is not air locked Locate the vent hole inspect and clear the hole using a pipe cleaner Pump Cycles Too Frequently 1 Check valve problem 1 Check to make s...

Page 10: ...R PUR POSE ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE THIS IS THE EXCLUSIVE REM E DY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAM AG ES OR EXPENSES WHATSOEVER IS EXCLUDED Som...

Page 11: ...l set to 4 rings the System set to 5 rings 1 Make a phone call to the System phone number at alarm location let ring three 3 times hang up 2 Make a second call to the System within 3 minutes the Syste...

Page 12: ...tr leur termin e r tablir l alimentation c a et v rifier la pompe principale conform ment la description donn e dans la section Fonctionnement de ce manuel Rouge Noir N inclut pas la batterie d charge...

Reviews: