background image

  

WSM3300

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

READ, UNDERSTAND AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL - DO NOT DISCARD.  

Failure to follow these instructions could result in property damage, bodily injury or death.

 

Battery acid is corrosive. Avoid spilling on skin or 

 

clothing. Eye protection MUST be worn when 

 

handling the battery.

 

A check valve MUST be used on the primary 

 

and back-up sump discharge.

 

A ground fault circuit interrupter is required. 

 

This pump MUST only be used to pump clear 

 

water. This pump is NOT designed to handle 

effluent, salt water, brine, laundry discharge, or any other application 

which MAY contain caustic chemicals and/or foreign materials. Pump 

damage MAY occur if used in these applications and WILL void warranty.

SPECIFICATIONS

CONSTRUCTION

DESCRIPTION

The 12 Volt Advanced Notification System includes a DC back-

up sump pump, an electronic controller with digital display, and 

an auto-dialer. Optimal back-up power is supplied by a 12 volt 

battery (not included). The system is designed for home sump 

applications. When an electrical power outage occurs, the 

electronic controller automatically switches the sump pump to 

battery power.  Power loss will initiate a phone call via the auto- 

dialer to the phone number(s) entered by the homeowner. With 

a 24-hour monitor and a predetermined full system check, the 

system tells you it’s status via a digital display and alerts you to 

potential problems with an audible horn and phone call. 

UNPACKING

Inspect this unit before it is used. Occasionally, products are 

damaged during shipment. If the pump or components are 

damaged, contact customer service at 1-800-237-0987.

SAFETY GUIDELINES

To help recognize this information, observe the following signal 

words/hazard classifications. 

 

This is the safety alert symbol. It is used to alert you to  

 

 

potential bodily injury hazards. Obey all safety messages that  

 

follow this symbol to avoid possible harm.

 

Danger indicates an imminently hazardous 

  situation which, if NOT avoided, WILL result  

 

in death or serious injury.

 

Warning indicates a potentially hazardous 

  situation which, if NOT avoided, COULD  

 

 

result in death or serious injury.

 

Caution indicates a potentially hazardous 

  situation which, if NOT avoided, MAY result   

 

in minor or moderate injury.

 

Notice indicates important information, that if 

  NOT followed, MAY cause damage to equipment.

GENERAL SAFETY INFORMATION

 

This pump is NOT rated for use with flammable/ 

 

combustible liquids vapors or dusts.  

Do NOT use to pump flammable/combustible liquids vapors 

or dusts. Do NOT use in a flammable and/or explosive 

atmosphere. Pump SHOULD be used to pump clear water 

ONLY. Failure to follow these instructions WILL result in bodily 

injury or death.
 

Electric shock hazard. Disconnect 

 

power before servicing. Apply a fixed 

lock or tag to prevent unexpected application of power.
 
 

Electric shock hazard. DO NOT walk    

 

on wet floor until power is disconnected. Use a 

licensed electrician to perform service in accordance with the National 

Electrical Code and all local codes.

© 2012, WAYNE/Scott Fetzer Company.

2

12 Volt Advanced 

Notification System

OPERATING INSTRUCTIONS & PARTS MANUAL

CALIFORNIA PROPOSITION 65

 

This product or its power cord MAY contain 

 

chemicals, including lead, known to the 

State of California to cause cancer and birth defects or other 

reproductive harm. Wash hands after handling. 

 

Explosion hazard. Smoking and open flames 

 

prohibited. Battery recharging and 

connections MUST be performed in a well ventilated area.

Power Supply Requirements ......120 V, 60 Hz 

Motor ..........................................12 V DC Motor 

Pump Dimensions ......................11 in. high x 8 3/4 in. base

Motor Housing ........................... 

Impeller ...................................... 

Shaft .......................................... 

Discharge ..................................  

Float Switch .............................. 

NEVER allow children to use pump.

 

Chemical hazard. If battery acid contacts  

 

your eyes, immediately flush eyes with 

copious amounts of clean, tepid water for at least 30 minutes. Seek 

medical attention.

BATTERY INFORMATION

The system is designed to operate most efficiently with a 

deep cycle, sealed lead (Pb) acid (SLA) battery. A deep cycle 

marine battery can also be used. Sealed lead acid batteries cost 

slightly more, but they can last longer than a wet cell battery and 

are maintenance free. The oversize battery case (included) will 

accomodate one 12 Volt battery up to a 27-frame size. Use a new 

battery. Chart 1 illustrates the expected performance with various 

battery combinations. Do not use batteries rated below 40 amp 

hours. Be certain that the area around the battery is well ventilated. 

Before servicing the battery, blow away gasses by waving a piece 

of cardboard near the battery. An assistant should be present or 

close enough to come to your aid in the event of an emergency. 

Have a reliable source of fresh water and soap nearby in case 

battery acid contacts clothing, skin or eyes. Wear eye and clothing 

protection when working around lead acid batteries. Avoid touching 

your eyes when working around lead acid batteries.

Thermoplastic 

Thermoplastic 

Stainless Steel 

1-1/2 in. NPT 

Dual Reed

INSTALLATION AND OPERATING INSTRUCTIONS

Summary of Contents for WSM3300

Page 1: ...able Batteries Transformer Wear safety glasses when connecting the battery STEP 5 CONNECT LID TO BATTERY Transformer 1 Lid and Controller Assembly 1 Battery box 1 12 Volt DC back up pump 1 Switch with...

Page 2: ...to equipment GENERAL SAFETY INFORMATION This pump is NOT rated for use with flammable combustible liquids vapors or dusts Do NOT use to pump flammable combustible liquids vapors or dusts Do NOT use i...

Page 3: ...separately to the top of the discharge pipe This will allow the pump or check valve to be removed easily for servicing 8 Check valve is recommended for effective operation of system The remainder of...

Page 4: ...pipe is required for permanent installation 9 Glue a 45 elbow to the short pipe on the Back Up DC Pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method 2 10...

Page 5: ...negative terminal of the battery The display should be lit up at this time If connected improperly an alarm will sound until corrected 4 Plug the pump and float switch connectors into the 12 Volt Adva...

Page 6: ...d phone number hit ENTER then select the TEST option The system will immediately dial the desired phone number Upon answering the unit will play the following message This is a test of the back up sys...

Page 7: ...up 3 Call the number a second time within three minutes The System keeps track of all the rings from the previous calls accumulates them until the total ring count matches its ring count number 5 or...

Page 8: ...E NUMBER REN The REN is used to determine the number of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices not ringing in response to an in...

Page 9: ...efective 5 Check to make sure the back up pump is not air locked Locate the vent hole inspect and clear the hole using a pipe cleaner Pump Cycles Too Frequently 1 Check valve problem 1 Check to make s...

Page 10: ...R PUR POSE ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE THIS IS THE EXCLUSIVE REM E DY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAM AG ES OR EXPENSES WHATSOEVER IS EXCLUDED Som...

Page 11: ...l set to 4 rings the System set to 5 rings 1 Make a phone call to the System phone number at alarm location let ring three 3 times hang up 2 Make a second call to the System within 3 minutes the Syste...

Page 12: ...tr leur termin e r tablir l alimentation c a et v rifier la pompe principale conform ment la description donn e dans la section Fonctionnement de ce manuel Rouge Noir N inclut pas la batterie d charge...

Reviews: