PHONE LINE INSTALLATION

PHONE SYSTEM INFORMATION

Sharing the phone jack:
The 12 Volt Advanced Notification System and your existing 

phone/fax can share the same wall jack. A standard phone 

jack splitter also known as a line splitter (not provided) can be 

purchased at your local hardware store. Install as shown in 

Figure 5. The splitter allows independent operation of both units 

without interference.

PHONE SERVICE AND POWER OUTAGES

The 12 Volt Advanced Notification System is designed and 

certified by the FCC to operate on a standard telephone line and 

connects to a standard phone jack. The System dials out using 

touch tone dialing only.  Must have an active phone line that is 

detectable by the 12 Volt Advanced Notification System. 
The 12 Volt Advanced Notification System does work with 

DSL, Cable, or Digital phone services with the appropriate 

in-line filters. If the modem doesn’t produce a “dial tone” it 

will not be able to place a phone call. If the 12 Volt Advanced 

Notification System is unable to place a call while using one of 

these services, please contact your phone service provider for 

assistance.

PHONE NUMBER ENTRY AND STORAGE

The 12 Volt Advanced Notification System uses an onboard 

auto-dialer and microprocessor to place pre-recorded phone 

calls regarding the status of your back-up system. The System 

is capable of notifying up to three phone numbers (60 digits 

each) of your choice. The System stores each of your phone 

numbers locally and will not lose or erase your phone numbers 

due to a power outage or battery dying. Before you start 

entering phone numbers, DO NOT enter phone numbers of 

emergency services (fire, police, or ambulance). 

CELL PHONES:

 The 12 Volt Advanced Notification System will 

call all phones that a basic telephone will connect with. It does 

not differentiate between a cellular phone or land line phone.  

Cellular calls are based upon having adequate reception.

Line Splitter 

(not provided)

12 Volt Advanced 

Notification System

1.  Place battery box and controller within six feet of the sump 

     and a 120 VAC separately fused outlet. The outlet must be 

     protected by a ground fault circuit interrupter (GFCI). The 

     area must also be clean, dry, and well-ventilated.
2.  Wave cardboard over batteries to blow away any gas that 

     may be present.
3.  Connect the power wires from the 12 Volt Advanced 

     Notification System to the battery terminals as shown in 

     (Figure 4). Connect the red wire to the positive 

     terminal of the battery and then connect the black wire  

     to the negative terminal of the battery. The display 

     should be lit up at this time. If connected improperly an 

     alarm will sound until corrected.
4.  Plug the pump and float switch connectors into the 

     12 Volt Advanced Notification System. The connections are 

     marked. (See Step 6 in the Quick Start Guide)
5.  Follow the on-screen instructions. Test pump operation 

     by filling the sump with water while the main pump is 

     unplugged. If the back-up pump operates properly, plug the 

     transformer into the GFCI protected outlet to begin charging 

     the battery.

Figure 4 - Battery terminal connection

Be sure to 

connect the 

cables as 

shown, reversing 

the cables will 

cause damage 

to the product.

Figure 5 - Phone line splitter/hookup

Open  

Phone Jack

If you have an 

open phone 

service jack 

available, a line 

splitter is not 

required.

Shared  

Phone Jack

Phone/FAX 

 Cord

 

 

Explosion hazard. Smoking and open 

 

flames prohibited. Battery 

recharging and connections MUST be performed in a well 

ventilated area. Before servicing the batteries, blow away 

the gases by waving a piece of cardboard near the batteries. 

Black

 

POWER OUTAGES: DSL, Digital, and Cable  

 

provided phone services DO NOT WORK 

when AC Power is lost. The 12 Volt Advanced Notification System 

will NOT be able to call out if the power is out when using these 

phone services. A back-up battery system (UPS-uninterrupted 

power supply) is required to keep the modem and/or system active 

for a minimum of 8 hours. Check with your phone service provider 

for details regarding UPS sizing for your installation. Standard 

telephone lines are self-powered by the telephone company and 

usually not affected unless the phone service itself is interrupted.

Operating Instructions and Parts Manual

WSM3300

 

If battery cables are reversed, damage to the 

 

transformer, controller or battery COULD 

 

result, and warranty WILL be void.

CONTROL BOX INSTALLATION

 

Use the system indoors, in a well ventilated 

 

area. Do NOT expose to rain or snow. Do NOT use 

an extension cord. Do NOT disassemble. Be sure battery box ventilation 

holes are unobstructed. If dropped or damaged, do NOT operate; contact 

manufacturer for service.

 

Electric shock hazard. Connect this 

 

transformer to a properly grounded  

GFCI (Ground Fault Circuit Interrupter) receptacle that is rated 

for at least 5 amps. Test the operation of the GFCI receptacle 

according to the manufacture's recommended intervals.
DISCONNECT AC power before connecting or disconnecting the battery.

Red

 

Protect electrical cord from sharp objects, hot 

 

surfaces, oil, and chemicals. Avoid kinking the 

cord and replace damaged components immediately.

            

      The phone cords 

may need to be longer depending 

upon the distance to the available 

phone service jack. 

www.waynepumps.com

Summary of Contents for WSM3300

Page 1: ...able Batteries Transformer Wear safety glasses when connecting the battery STEP 5 CONNECT LID TO BATTERY Transformer 1 Lid and Controller Assembly 1 Battery box 1 12 Volt DC back up pump 1 Switch with...

Page 2: ...to equipment GENERAL SAFETY INFORMATION This pump is NOT rated for use with flammable combustible liquids vapors or dusts Do NOT use to pump flammable combustible liquids vapors or dusts Do NOT use i...

Page 3: ...separately to the top of the discharge pipe This will allow the pump or check valve to be removed easily for servicing 8 Check valve is recommended for effective operation of system The remainder of...

Page 4: ...pipe is required for permanent installation 9 Glue a 45 elbow to the short pipe on the Back Up DC Pump Glue a Y adapter to the short pipe on the existing pump as shown in illustration for Method 2 10...

Page 5: ...negative terminal of the battery The display should be lit up at this time If connected improperly an alarm will sound until corrected 4 Plug the pump and float switch connectors into the 12 Volt Adva...

Page 6: ...d phone number hit ENTER then select the TEST option The system will immediately dial the desired phone number Upon answering the unit will play the following message This is a test of the back up sys...

Page 7: ...up 3 Call the number a second time within three minutes The System keeps track of all the rings from the previous calls accumulates them until the total ring count matches its ring count number 5 or...

Page 8: ...E NUMBER REN The REN is used to determine the number of devices that may be connected to a telephone line Excessive REN s on a telephone line may result in the devices not ringing in response to an in...

Page 9: ...efective 5 Check to make sure the back up pump is not air locked Locate the vent hole inspect and clear the hole using a pipe cleaner Pump Cycles Too Frequently 1 Check valve problem 1 Check to make s...

Page 10: ...R PUR POSE ARE LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE THIS IS THE EXCLUSIVE REM E DY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAM AG ES OR EXPENSES WHATSOEVER IS EXCLUDED Som...

Page 11: ...l set to 4 rings the System set to 5 rings 1 Make a phone call to the System phone number at alarm location let ring three 3 times hang up 2 Make a second call to the System within 3 minutes the Syste...

Page 12: ...tr leur termin e r tablir l alimentation c a et v rifier la pompe principale conform ment la description donn e dans la section Fonctionnement de ce manuel Rouge Noir N inclut pas la batterie d charge...

Reviews: