LIMITED WARRANTY

For three years for SWS50, SWS75, and SWS100 models from the date of purchase, from an authorized dealer, Wayne Water Systems will repair or replace, at its option 

for the original purchaser, any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne Water Systems to be defective in 

materials or workmanship. Please call Wayne Water Systems (888-636-6628) for instructions. Be prepared to provide the model number and the serial number when 

exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser. This Limited Warranty is not 

transferrable.This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper 

maintenance, or failure to operate in accordance with WAYNE’s written instructions.
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, 

or failure to operate in accordance with Wayne Water Systems’ written instructions.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE 

LIMITED TO ONE YEAR FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL 

DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED.

In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne Water Systems or its suppliers be liable for any 

special, consequential, incidental or penal damages.
You 

MUST

 retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you 

MUST

 send a 

copy

 of the purchase receipt along 

with the material or correspondence. Please call Wayne Water Systems (888-636-6628) for return authorization and instructions.

DO NOT MAIL THIS FORM TO Wayne Water Systems.

 Use this form only to maintain your records.

MODEL NO._____________________  SERIAL NO._________________________ INSTALLATION DATE __________________________

ATTACH YOUR RECEIPT HERE

Summary of Contents for 64043-WYN1

Page 1: ...d protect from sharp objects hot surfaces oil and chemicals Replace damaged or worn cords immediately 15 Keep fingers and foreign objects away from ventilation and other openings Do NOT insert any obj...

Page 2: ...llon precharged tank will have the same usable water or drawdown capacity as a 40 gallon conventional tank but the tank is smaller in size Figure 1 PRESSURE SWITCH The pressure switch provides for aut...

Page 3: ...the pipe and cause abnormal pump operation Make sure to use pipe joint compound on all male pipe threads DUG WELL CISTERN LAKE AND SPRING INSTALLATION FIGURE 12 ON PAGE 9 1 Install a foot valve on in...

Page 4: ...o the metal well casing or use a ground electrode furnished by the power company There is only one proper ground terminal on the unit The terminal s is located under the pressure switch cover is paint...

Page 5: ...Priming the Shallow Well Pump on page 4 4 Reconnect the power to the pump NOTE As the pump refills the tank with water the air volume control supplies the tank with the correct air to water ratio for...

Page 6: ...so the two screw holes are on a horizontal line across the motor shaft Figure 10 This placement should be done to ensure proper draining and priming 3 Place rotating shaft seal member in position on i...

Page 7: ...ed to keep the ceramic face clean You can use a little water or dish soap to lubricate the seal pocket to make assembly easier 16 Slide the square cut gasket over the flange on the seal plate make sur...

Page 8: ...ed 6 Replace air volume control 7 Foot valve may be clogged or stuck closed 7 Clean or replace as needed 8 Pump not fully primed 8 Continue priming paus ing ev ery 5 minutes to cool pump body Refill p...

Page 9: ...rick stone or concrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 thro...

Page 10: ...e been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with Wayne Water Systems written instructions THERE IS NO OTH...

Page 11: ...es aceite y qu micos Reemplace los cables da ados o desgastados de inmediato 15 Mantenga los dedos y objetos extra os lejos de la ventilaci n y otras aberturas NO inserte ning n objeto en el motor Rie...

Page 12: ...n tanque precargado de 20 galones rendir la misma cantidad de agua utilizable o capacidad de vaciado que un tanque convencional de 40 galones con la ventaja de que el tanque es m s peque o Figura 1 PR...

Page 13: ...de pedestal tipo tap n siga las instrucciones del fabricante Como alternativa se puede usar una v lvula de retenci n en l nea con un pozo accionado Figura 2 Ilustraci n C La tuber a entre la v lvula d...

Page 14: ...r nea met lica o una cubierta de pozo de al menos 10 pies largo son los mejores electrodos de tierra Si se usa tuber a de pl stico o adaptadores con aislamiento pase un cable directamente a la armaz n...

Page 15: ...agua el control de volumen de aire suministra al tanque la relaci n adecuada de aire y agua para que el sistema funcione Si el control de volumen de aire est bien la bomba se apagar en el nivel l mite...

Page 16: ...rizontal a trav s del eje del motor Figura 10 Esta ubicaci n se debe hacer para asegurar un drenaje y cebado adecuados 3 Sit e la pieza giratoria del sello del eje en el impulsor y presi nela para que...

Page 17: ...Se puede utilizar un poco de jab n y agua o un plato para lubricar el sello de bolsillo para facilitar el montaje 16 Deslice la junta de corte cuadrado sobre la brida en la placa de sellado aseg rese...

Page 18: ...de aire 7 La v lvula de pedestal puede estar obstruida o atascada 7 Limpie o reemplace de ser necesario 8 La bomba no est totalmente cebada 8 Contin e cebando pausando 5 minutos para enfriar el cuerp...

Page 19: ...D O Se acci ona una t uber a con una pant al l a con punt a en l a t i er r a por debaj o de l a capa f r e t i ca La pr of undi dad por l o gener al es m enor a 15 25 m 50 pi es Los di m et r os com...

Page 20: ...idente abuso mal uso negligencia instalaci n incorrecta mantenimiento inadecuado o falla en operar de acuerdo con las instrucciones escritas de Wayne Water Systems NO EXISTE NINGUNA OTRA GARANT A EXPR...