background image

Engine Driven 
Semi-Trash
Pump

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.

1

Operating Instructions and Replacement Parts List

GPH400 and GPH550

The Wayne pumps are general use
centrifugal water pumps.

This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols. 

Danger indicates
an imminently

hazardous situation which, if not avoided,
will result in death or serious injury.

Warning indicates 
a potentially

hazardous situation which, if not avoided,
could result in death or serious injury.

Caution indicates a 
potentially

hazardous situation which, if not avoided,
may result in minor or moderate injury.

Notice indicates 

important

information, that if not followed, may
cause damage to equipment.

1.  Know the pump application,

limitations, and potential hazards.
Read these rules and the instructions
carefully. Failure to follow them could
cause serious bodily injury and/or
property damage.

Never run engine in an
enclosed area. Exhaust gases
contain deadly poisonous carbon
monoxide, which has no odor or taste.

320802-001 12/03

Do not use to pump flammable
or  explosive fluids such as
gasoline, fuel oil, kerosene, etc.  Do not
use in flammable and/or explosive
atmospheres. Pump should only be used
with liquids compatible with pump
component materials. Failure to follow
this warning can result in personal injury
and/or property damage.

2. Observe all safety precautions for the

handling of the fuel. 

Do not refuel a hot engine.
Fuel spilled on a hot engine
could result in a fire or explosion. Do not
refuel a running engine.

3. Pump should be located and should

rest on a level solid foundation. Do
not suspend pump by means of the
discharge pipe.

Be sure pump is on 

secure footing so it

doesn’t fall over.

4. Do not use torches or apply excessive

heat, fire or flames to this pump as an
explosion may result.

5. Before working on the unit, insulate

the wire from the spark plug,
disconnect the spark plug wire and
mount it on the grounding clip.

Complete pump 

and piping system

MUST be protected against below
freezing temperature. Failure to do so
could cause serious damage and voids
the warranty.

6.

Do not run pump dry. Water is
required to lubricate the shaft
seal.

7. Pumping chemicals or corrosive

liquids with this pump may shorten

the life of the pump and may be
hazardous to the operator.

8. Personal Safety:

a. Wear safety glasses at all times

when working with pumps.

b. Keep work area clean, uncluttered

and properly lighted; replace all
unused tools and equipment.

c. Keep visitors at a safe distance from

the work area.

d. Make workshop child-proof with

padlocks, master switches, and by
removing starter keys. 

9. Always use a suction strainer with this

pump to filter large material. 

This pump is designed to be self-
priming when installed and operated as
specified below.

1. The pump should be placed as close

as possible to the liquid being
pumped. A pump with 20 foot
suction lift will not remove water as
quickly as a pump with 5 foot
suction lift (Figure 1).

2. Suction hose and fitting must be

airtight.

Description

Safety Guidelines

General Safety
Information

Installation

Figure 1

20 Ft.
Suction Lift

5 Ft.

Suction

Lift

Summary of Contents for 320802-001

Page 1: ...onent materials Failure to follow this warning can result in personal injury and or property damage 2 Observe all safety precautions for the handling of the fuel Do not refuel a hot engine Fuel spille...

Page 2: ...n 11 Move choke lever to CHOKE position 12 Move throttle lever to START position 13 Pull engine crank until engine starts Once engine starts move choke lever to RUN position 14 The pump will take seve...

Page 3: ...20 2 30 5 11 2 2 6 4 0 5 5 9 4 14 3 19 9 34 2 2 1 2 1 6 2 8 4 2 5 8 9 9 15 0 21 2 21 2 1 2 1 8 2 5 4 2 6 3 8 8 Performance Information Semi Trash Pump Performance Discharge Head Gallons Hour GPH550 GP...

Page 4: ...ose thread One 20 ft hose per carton 2 SUCTION STRAINER PART 66036 Prevents stones leaves and other debris from clogging pump For Pump Accessories call 1 800 237 0987 Please provide following informat...

Page 5: ...Plug 28444 001 28444 001 2 7 Impeller 41021 001 41020 001 1 8 Wear Plate 72030 001 72031 001 1 9 Volute 72032 001 72033 001 1 10 Volute Seal 19051 001 19052 001 1 11 Seal Plate TX2 72027 001 72029 001...

Page 6: ...IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the above limitations mi...

Page 7: ...pour ne pas basculer 4 Ne pas utiliser de chalumeaux ni de chaleur excessive feu ou flammes sur cette pompe car il pourrait y avoir une explosion 5 Avant d utiliser l appareil isoler le fil des bougi...

Page 8: ...levier d tranglement la position RUN 14 La pompe peut prendre quelques minutes s amorcer TUYAUTERIE Placez la pompe aussi pr s que possible du liquide pomp Gardez tous les tuyaux et flexibles aussi c...

Page 9: ...4 2 5 8 9 9 15 0 21 2 21 2 1 2 1 8 2 5 4 2 6 3 8 8 Information sur la performance Performance de la pompe r sidus T te de d charge Gallons Heure GPH550 GPH400 PERFORMANCE DU GAZ PERFORMANCE DU GAZ Mod...

Page 10: ...et de tuyau de 2 po Un tuyau de 20 pieds par carton CR PINE D ASPIRATION DE 2 PO PIECE NO66036 Emp che les pierres feuilles et autres d bris de bloquer la pompe Pour les accessoires de pompe appele 1...

Page 11: ...sage 28444 001 28444 001 2 7 Rotor 41021 001 41020 001 1 8 Plaque d usure 72030 001 72031 001 1 9 Volute 72032 001 72033 001 1 10 tanch it de volute 19051 001 19052 001 1 11 Plaque d tanch it TX2 7202...

Page 12: ...r e pour les garanties implicites ni l exclusion ni la limite des dommages fortuits ou indirects Les limites pr c dentes peuvent donc ne pas s appliquer Cette garantie limit e donne l acheteur des dro...

Reviews: