![Wavion WS-410AD Installation Manual Download Page 29](http://html1.mh-extra.com/html/wavion/ws-410ad/ws-410ad_installation-manual_878220029.webp)
Installing the Wavion WS-410 Metro Access Point
Installation Guide
29
Figure 3.17. Connecting Category C AC Power
To connect an AC power source
1.
Verify that the service voltage is the following:
•
NEMA plug, for streetlight photoelectric control power tap (2-wire service) —2W(2P) or
2W(P+N); 100-240 VAC 50/60 Hz. See
Chapter 7: Installation Accessories
for
details.
2.
Make sure the power is turned off on the designated circuits.
3.
Install a 1/2 inch liquid-tight conduit from the building entrance point to within 3 feet of
the outdoor system.
4.
Run 3-wire AC service through the conduit.
AC power
from meter
To outdoor unit
AC wiring in junction box
according with WS-410
power supply
To power source
Black wire
White wire
Green wire
Wire nuts