Installing the Wavion WS-410 Metro Access Point
12 Wavion
Choosing a Location
The Wavion WS-410 is a radio device and susceptible to interference that can reduce
throughput and range. To ensure the best performance follow these guidelines:
•
Direct line-of-sight operation is preferred.
•
It is recommend not to install the WS-410 near devices operating in the 2.4 GHz
frequency range.
Preparing the Site
When installing the Wavion WS-410, you must follow the appropriate electrical and building
codes to ensure sage and durable wiring. Follow the National Electrical Code (NEC)
requirements, unless local codes in your area take precedence over the NEC code. For
installations that have 10/100 Base-T Category 5 network cables attached to the Wavion WS-
410, there is a distance limit of 100m maximum between devices for 10/100BaseT operation.
Please refer to standards for building entrance protection.
Power Source Options
The Wavion WS-410 supports the following options for connecting to a power source:
•
AC power source (3-wire service) — 3W(P+N+PE) or 3W(2P+PE); 110-220 VAC, 50/60
Hz. See
Chapter 7: Installation Accessories
for details.
•
NEMA plug, for streetlight photoelectric control power tap (2-wire service) —2W(2P) or
2W(P+N); 100-240 VAC 50/60 Hz. See
Chapter 7: Installation Accessories
details.
•
The WS-410 can be powered by a Wavion Injector connected to Ethernet port B (ETH B).
See
Chapter 7: Installation Accessories
for details.
W
ARNING
:
480 VAC power source is supported by a WS-410 unit only by using a
special street light step down power tap. See
.
W
ARNING
:
Use only a rated power source to connect the AC powered outdoor
system. Do not connect to a power source of different voltage.
C
AUTION
:
You must always install an external grounding wire. You must also ground
the outdoor data protection device to a bonded pipe or ground rod. Perform a simple
continuity check between the WS-410 and the ground termination point to confirm.
Make sure that grounding is complete before you connect power to the Wavion WS-
410.
Summary of Contents for WS-410AD
Page 1: ...WS 410AD Metro Access Point Installation Guide June 2007...
Page 8: ...Introduction 8 Wavion Networks...
Page 42: ...Power Consumption 42 Wavion...
Page 46: ...Product Specification 46 Wavion...
Page 49: ...Antenna Specifications and Patterns Installation Guide 49...
Page 50: ...Antenna Specifications and Patterns 50 Wavion...
Page 51: ...Antenna Specifications and Patterns Installation Guide 51...
Page 52: ...Antenna Specifications and Patterns 52 Wavion...
Page 56: ...Installation Accessories 56 Wavion...
Page 62: ...Wind Loading Considerations 62 Wavion...
Page 64: ...Backhaul Unit Installation Instructions 64 Wavion...