42
CHAPTER 4
•
WEB INTERFACE
Channel Failsafe
The
Failsafe Timeout
field has a value that determines how long the Click 65x waits without
receiving communication from any of the attached devices before it considers that device
to be in failsafe condition. This timeout (expressed in milliseconds) should be high enough
to avoid natural communication delays due to normal network conditions, but low enough
to properly notify operators of device communication failures in a timely enough manner.
When a sensor is put in failsafe state by the Click 65x, administrators have the option of
having detection channels assigned to that sensor either produce a constant call, or no call
at all. This option can be toggled through the
Constant Call
and
No Call
radio buttons.
Push the
Save
button after making any adjustments to save the admin settings to the device
configuration.
Trigger Speed Message Forwarding
This allows trigger speed messages from the SmartSensor Advance to be forwarded to an
application that is listening on a UDP port. For more information on using this feature,
please contact Wavetronix.
Security Settings
Here you can select the Password Protect checkbox to set up a password for the software. If
you do this, the software will ask for a password on any page where you try to save changes
(only during the first save of your current session). Should you ever lose this password, it
can be cleared on the device itself, in the OLED panel menu. You can also contact Wavetro-
nix technical services for assistance.
Push the
Save
button after making any adjustments.
Sensors
You can turn on or off any of the sensor ports, as well as set the baud rate. All ports will be
activated by default (whether or not they have sensors plugged into them); uncheck any of
the four/six ports to deactivate them. The ports do not have to be active or inactive in any
order—any of them can be toggled as needed—but any port with a sensor attached needs
to be active to receive sensor channel events. The baud rate for communication on any port
can also be adjusted by selecting a baud rate from the drop-down list.
Push the
Save
button after making any adjustments.
Summary of Contents for Click 65 Series
Page 1: ...Click 65x Series USER GUIDE...
Page 5: ......
Page 25: ......
Page 45: ......
Page 49: ...48 APPENDIX Figure A 3 TS2 Type 2 Operating like a TS1...