28
CHAPTER 4
•
WEB INTERFACE
Sensors Tab
Figure 4.2 – Sensors Tab
When the Click 65x is being configured for the first time, this screen will be empty, as no
sensors have yet been discovered and registered. Prior to adding sensors through the web
interface, ensure that the sensors are connected to the proper port on the back of the unit
and the power switch on the front of the unit is turned on.
Note
It is recommended that you complete sensor configuration before Click 65x discovery.
During discovery, the device saves the current sensor channel configuration to the
device for use in channel mappings. Subsequent changes to sensor configuration will
not automatically be updated within the Click 65x; that sensor will need to be redis-
covered on this page before the web interface will reflect the new changes.
The Click 650 and 656 feature auto-discovery, so you can press the
Discover Matrix Sen-
sors
and/or
Discover Advance Sensors
buttons and the system will automatically query all
data ports for each type of device and display any discovered device to the screen.
Note
Advance device discovery typically takes a longer time than Matrix discovery.