22
APCD-LM048-1.1
4: Installation
Table 4 Installation Stage Checklist
Once the installation is complete and verified, the network operator can complete the Post-
installation Stage, using the Automatic Remote Configuration feature or manually over the air.
This is discussed in
Step
Discussion
Find the best location for mounting the EUM3006, with a
good RF signal and at least 1 foot away from where
people will stand.
The EUM3006 mounts to a vertical pole with a diameter
between 1 and 3.0 inches. Once a location with good
signal levels is found, attach pole mounting hardware
such as a standard Satellite TV mount, to the building or
support structure. Attach the EUM3006 to the pole with
the mounting plate and the two gear clamps.
Run the Ethernet cable from the modem to the PoE
Injector and run the grounding conductor to a suitable
grounding location.
Connect the modem to a power source, usually the PoE
injector provided.
Connect the modem to the end-user’s PC.
Confirm that the link is functioning correctly.