7.7.6 EMS communication
An EMS communication cable needs to be connected to control the operation of a hybrid inverter through the EMS, and
communication between EMS and inverter is RS485.
7.7.7 Dred
DRED interface is specially reserved for Australia and New Zealand according to their safety regulation, and Wattsonic
doesn’t provide the DRED device for the customer.
There is a resistor between 15(COM D/0) and 16(REF D/0); do not move the resistor while wiring.
7.7.8 Multifunction relay
The inverter is equipped with a multifunction dry contact relay, which helps turn the loads on or off when an extra
contactor is connected, or startup the diesel generator when the diesel generator startup signal is connected.
Maximum voltage and current at DO dry contact port: 230VAC 1A/30VDC 1A.
For more installation and setup information, please contact Wattsonic.