User Manual
73
Error Message Description Solution
GFCI Fault
PV Over Volt¬age
Bus Voltage Fault
Inverter Over
Temperature
N-PECheck Fault
SPI Fault
E2 Fault
GFCI De vice Fault
AC Transducer Fault
Relay Check Fail
The inverter detects that the
ground leakage current exceeds
the limitation.
PV input voltage exceeds the
upper limit.
The voltage of bus circuit is too
high
The inverter detects its high
internal temperature
The ground cable is losse or in
poor connection
Internal communication got
failed. Caused by a strong
external magnetic field etc.
Internal storage got abnomal.
Caused by a strong external
magnetic field etc.
GFCI device got abnormal
AC transducer got abnomal
Self-checking of internal relay
got failed. Neutral & ground
1. Restart the inverter.
2. Check whether the PV panels, cables, and
connectors are waterlogged or damaged.
3. Seek help from the installer or manufacture.
Reduce the number of PV panels to make sure
that the open-circuit voltage of each string is
lower than the inverter maximum allowed input
voltage.
1. Check whether the input voltage exceeds the
limit.
2. Restart the inverter.
3. Seek help from the installer or manufacture.
1.Check whether the inverter installation location
is well ventilated.
2.Try to turn it off for a while, and then power it
back on when it cools down.
3.Seek help from the installer or manufacture.
Check whether the ground cable wiring is
cor¬rect.
1. Restart the inverter.
2. Seek for help from the installer or manufacture.
1. Restart the inverter.
2. Seek help from the installer or manufacture.
1. Restart the inverter.
2. Seek for help from the installer or manufacture.
1. Restart the inverter.
2. Seek for help from the installer or manufacture.
1. Use multimeter to measure the voltage
be¬tween N&PE cable on AC side. If the voltage
is higher than 10V, which means the neutral or