Water supply line to the system must be from the cold water supply line only.  Hot water 

connection is used for rinse water return and must be connected for system to function correctly.

Reverse Osmosis Module Mounting

Step 12

Turn off the cold and hot water supply to the faucet by turning the angle stop valves completely 
off. Open cold and hot water sink faucet to relieve pressure.

Step 10

Step 11

Choosing the configuration that fits your plumbing, attach the adapt-a-valves as illustrated in 

the photos above.

Adapt-a-Valve Installation

Do not use Teflon tape with the Adapt-a-Valve.

WARNING:

3/8” Configuration 

(With Brass Fittings)

* Insert White Washer

1/2” Configuration

(Without Brass Fittings)

 

*

White

Washer

Hot

Supply

Cold

Supply

Verify contents prior to installation:

( 2 ) - Plastic Adapt-a-Valve with black collet 
( 2 ) - Brass Adapter no washer
( 2 ) - Brass Adapter with black washer  
( 2 ) - White rubber washer

Make sure that the black collet is installed in to the 1/4” opening on the Adapt-a-valve.

Don’t forget to install the white compression washer with the 3/8” configuration.

Brass adapter (A) does not need to be tightened with a wrench, only finger tight.

Black 

Collet

A

TIPS:

A

White

Washer

Connect the Green and Red Tubing

Step 13

In the parts bag locate the 1/4” green tubing. Insert one open end of the green 1/4” tube into 

the open 1/4” quick connect fitting on the 

COLD 

water feed adapta-a-valve making sure the 

tube is pushed in all the way to the tube stop. Repeat the procedure to connect red tubing 
attached to the RO module to connect to the hot water, return adapt-a-valve.

Determine best location for the RO module to be mounted to allow  
for future system maintenance.  Using the mounting holes on the 
bracket, mark the location for the mounting screws on the cabinet 
wall under the sink. In the parts bag, locate the two self  tapping 
screws.  Using an electric drill with a Phillips bit, screw them into 
the cabinet at the marked location. Hang the module on the screws 
using the mounting holes in the bracket

Summary of Contents for ZRO-PURE

Page 1: ...Inc 8716 W Ludlow Drive Suite 1 Peoria AZ 85381 Phone 800 752 5582 www wattspremier com Fax 623 866 5666 Save manual for future reference Warning Please read carefully before proceeding with installat...

Page 2: ...ed change 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recom...

Page 3: ...Tube Connection From Adapt A Valve to Pump 9 Green Tube Connection From RO System to ESOV 9 Blue Tube Connection From RO System to ESOV 9 Blue Tube Connection ESOV 9 Tank Ball Valve Installation 10 Bl...

Page 4: ...Maximum 100 F 37 8 C Minimum 40 F 4 4 C Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 180...

Page 5: ...TUBE ZRO PURE Storage Tank Booster Pump Transformer ADAPTA VALVE HOT COLD Plumbing Diagram and Parts List Not recommended for use on homes equipped with tankless water heaters Contact Watts Premier fo...

Page 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Page 7: ...rt all the way into the end of the tube See Picture Insert the blue tube into the end of the faucet shank and use a wrench to tighten the brass nut securely Step 9 This faucet provides an electronic m...

Page 8: ...ake sure that the black collet is installed in to the 1 4 opening on the Adapt a valve Don t forget to install the white compression washer with the 3 8 configuration Brass adapter A does not need to...

Page 9: ...e to Pump Insert the open end 1 4 green tube from the Adapt a Valve into the 1 4 open end of the booster pump quick connect union Make sure the tube is pushed in all the way to the tube stop Green Tub...

Page 10: ...be stop see page 9 for quick connect fitting use directions Step 20 Note Set the blue ball valve knob in line with the blue tube this is the open position Teflon tape must be applied in a clockwise di...

Page 11: ...hours to fill Note If no water comes out of the RO faucet after a few minutes check the power outlet It is possible that the power outlet you used for the RO unit is controlled by the garbage disposal...

Page 12: ...ge However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to replace the membrane Premier recommends replacing the membr...

Page 13: ...tem Plug in the transformer Check frequently over the next 24 hours to ensure no leaks are present Step 4 Step 3 Note Step 2 Close the RO faucet allowing the storage tank to fill with water It may tak...

Page 14: ...upply to the RO and unplug transformer Open the RO Faucet and allow water to drain from the tank until it is completely empty Step 2 Check air pressure in the storage tank when you notice a decrease i...

Page 15: ...Air Gauge for best results The empty tank pressure should be 5 7 psi See page 14 4 Noise Water from faucet Crimp or restriction Check tubing and straighten or repair as necessary vent hole or noise f...

Page 16: ...0 ml 3 ml 99 99 7 44 50psi 18 minimum 50 000 mL N A Fluoride Reduction 8 7 0 19 97 0 7 24 50psi 0 3 8 0 10 1 5 Lead Reduction 0 15 0 002 98 8 7 39 50psi 0 005 0 15 10 0 0107 Nitrate 27 3 8 86 0 7 24 5...

Page 17: ...ee chlorine or combined chlorine is used in the water system This Premier reverse osmosis system is designed to remove up to 98 of pentavalent arsenic It will not convert trivalent arsenic to pentaval...

Page 18: ...Page 18 Nitrate Nitrite Test Instruction...

Page 19: ...nge kit which includes all replacement filters needed Call 1 800 752 5582 or buy on line at www wattspremier com All prices subject to change without notice Connect your RO Pure system to your refrige...

Page 20: ...Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 All In One reversible High Flow Filter Replacement filter Deluxe 5 Way Massaging Spray S...

Page 21: ...the safety of your personal information Premier collects personal information when you register with Premier This information is stored in our data base and we do not rent sell or share personal info...

Page 22: ...y USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of Purchase ___________________ Date of Install _______________________ Installed By...

Page 23: ...rchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months Carbon Post Filter 12months Model Number ____...

Page 24: ...g water pressure must be between 40 and 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do...

Reviews: