After drilling, remove all sharp edges and make sure the surroundings 
of the sink are cooled before mounting  the faucet.

Step 3

Step 4

Determine desired  location  for  the RO faucet on your sink and place 
a piece of masking tape over where the hole is  to be drilled.  Mark the 
center of the hole on the tape.

Step 1

Using a variable speed drill set on the slowest speed, drill a 1/8“ pilot 
hole through both porcelain and metal casing of sink at the marked 
center of  the desired location. Use lubricating oil or liquid soap to keep 
the drill bit  cool (If drill bit gets hot it may cause the porcelain to crack 
or chip). 

Using a 1 

¼

” diamond tip hole saw, proceed to drill the large hole.  Keep 

drill speed on  the  slowest speed and use lubricating oil or liquid soap 
to keep the hole saw cool during cutting.

Step 2

Counter Top / Porcelain & Stainless Steel Sink

Note:

Most sinks are pre drilled with 1 ¼” diameter hole that you can use for your RO faucet. 
(If you are already using it for a sprayer or soap  dispenser, see step 1)

Porcelain sinks are extremely hard and can crack or chip easily.  
Use extreme caution when drilling.  Watts  accepts no responsibility for 
damage resulting from the installation of faucet. Diamond tip bit recommended.

Marble Counter-top

We recommend contacting a qualified contractor for drilling a hole in a 

marble counter-top.

Drill a Hole for the Reverse Osmosis Faucet

How to use the Quick Connect Fittings

To make a connection, the tube is simply pushed into the fitting.  The unique locking system holds the tube firmly in place 

without deforming it or restricting flow. Use the steps below in reference to any quick connect tube connections.

It is essential that the outside diameter be free of score 
marks and that burrs and sharp edges be removed before 

inserting into fitting.

Fitting grips before it seals.  Ensure tube is pushed into 

the tube stop.

Push the tube into the fitting, to the tube stop.  The collet 

(gripper) has stainless steel teeth which hold the tube 

firmly in position while the O-ring provides a permanent 

leak proof seal.

Pull on the tube to check that it is secure.  It is a good practice 

to test the system prior to leaving site and /or before use.

To disconnect, ensure the system is 

depressurized before removing the tube.  Push in the col-

lect  squarely  against  face  of  fitting.    With  the  collet  held 
in this position, the tube can be removed.  The fitting can 

then be reused.

Summary of Contents for ZRO-PURE

Page 1: ...Inc 8716 W Ludlow Drive Suite 1 Peoria AZ 85381 Phone 800 752 5582 www wattspremier com Fax 623 866 5666 Save manual for future reference Warning Please read carefully before proceeding with installat...

Page 2: ...ed change 6 months The second stage contains a 5 micron carbon block filter This helps ensure that chlorine and other materials that cause bad taste and odor are greatly reduced Stage 3 Membrane recom...

Page 3: ...Tube Connection From Adapt A Valve to Pump 9 Green Tube Connection From RO System to ESOV 9 Blue Tube Connection From RO System to ESOV 9 Blue Tube Connection ESOV 9 Tank Ball Valve Installation 10 Bl...

Page 4: ...Maximum 100 F 37 8 C Minimum 40 F 4 4 C Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 180...

Page 5: ...TUBE ZRO PURE Storage Tank Booster Pump Transformer ADAPTA VALVE HOT COLD Plumbing Diagram and Parts List Not recommended for use on homes equipped with tankless water heaters Contact Watts Premier fo...

Page 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Page 7: ...rt all the way into the end of the tube See Picture Insert the blue tube into the end of the faucet shank and use a wrench to tighten the brass nut securely Step 9 This faucet provides an electronic m...

Page 8: ...ake sure that the black collet is installed in to the 1 4 opening on the Adapt a valve Don t forget to install the white compression washer with the 3 8 configuration Brass adapter A does not need to...

Page 9: ...e to Pump Insert the open end 1 4 green tube from the Adapt a Valve into the 1 4 open end of the booster pump quick connect union Make sure the tube is pushed in all the way to the tube stop Green Tub...

Page 10: ...be stop see page 9 for quick connect fitting use directions Step 20 Note Set the blue ball valve knob in line with the blue tube this is the open position Teflon tape must be applied in a clockwise di...

Page 11: ...hours to fill Note If no water comes out of the RO faucet after a few minutes check the power outlet It is possible that the power outlet you used for the RO unit is controlled by the garbage disposal...

Page 12: ...ge However if at any time you notice a reduction in water production or an unpleasant taste in the reverse osmosis water it could be time to replace the membrane Premier recommends replacing the membr...

Page 13: ...tem Plug in the transformer Check frequently over the next 24 hours to ensure no leaks are present Step 4 Step 3 Note Step 2 Close the RO faucet allowing the storage tank to fill with water It may tak...

Page 14: ...upply to the RO and unplug transformer Open the RO Faucet and allow water to drain from the tank until it is completely empty Step 2 Check air pressure in the storage tank when you notice a decrease i...

Page 15: ...Air Gauge for best results The empty tank pressure should be 5 7 psi See page 14 4 Noise Water from faucet Crimp or restriction Check tubing and straighten or repair as necessary vent hole or noise f...

Page 16: ...0 ml 3 ml 99 99 7 44 50psi 18 minimum 50 000 mL N A Fluoride Reduction 8 7 0 19 97 0 7 24 50psi 0 3 8 0 10 1 5 Lead Reduction 0 15 0 002 98 8 7 39 50psi 0 005 0 15 10 0 0107 Nitrate 27 3 8 86 0 7 24 5...

Page 17: ...ee chlorine or combined chlorine is used in the water system This Premier reverse osmosis system is designed to remove up to 98 of pentavalent arsenic It will not convert trivalent arsenic to pentaval...

Page 18: ...Page 18 Nitrate Nitrite Test Instruction...

Page 19: ...nge kit which includes all replacement filters needed Call 1 800 752 5582 or buy on line at www wattspremier com All prices subject to change without notice Connect your RO Pure system to your refrige...

Page 20: ...Plated Finish Reversible Filter Cartridge Model HHC Cartridge Life Rating 3 months Part No 107095 CHROME 55 95 All In One reversible High Flow Filter Replacement filter Deluxe 5 Way Massaging Spray S...

Page 21: ...the safety of your personal information Premier collects personal information when you register with Premier This information is stored in our data base and we do not rent sell or share personal info...

Page 22: ...y USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of Purchase ___________________ Date of Install _______________________ Installed By...

Page 23: ...rchase __________ Date of Install ___________ Installed by _____________ NOTES Date Sediment Filter 6 months Membrane 2 5 years Carbon Pre Filter 6 months Carbon Post Filter 12months Model Number ____...

Page 24: ...g water pressure must be between 40 and 85 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do...

Reviews: