Congratulations!
You have completed the installation of your new Reverse Osmosis system.
Please Follow the Startup Instructions.
Flushing of the tank 3 times is only necessary during the initial startup and after replacing
the membrane.
Note:
Start up Instructions
Step 1
Turn on the incoming hot
and
cold water angle stop valves.
Turn both of the adapt-a-valves on and check the system for leaks and tighten fittings
as
necessary.
Note:
Check daily over the next week
to ensure no leaks are present.
Step 2
Plug the (24 volt) transformer
power cord connector into the
ESOV as pictured.
Step 3
Plug the transformer into the
electrical outlet under the sink.
Step 4
Ensure ball valve on tank is open.
Step 5
Open the RO faucet and leave it
open until water begins to drip.
Then close the faucet.
The tank will take between 2 - 4
hours to fill.
Note:
If no water comes out of the RO
faucet after a few minutes check
the power outlet! It is possible that the power outlet you used for the RO unit
is controlled by the garbage disposal switch. To test - Unplug the garbage
disposal and flip the garbage disposal switch to “on” . If the RO pump turns on
and water starts to drip out of the RO faucet you will need to connect the system
to a different power outlet socket.
Step 6
After the tank has filled once, open the RO faucet and drain the tank.
Note:
Water may be cloudy or milky due to air in the system and carbon particles flushing out
of the final polishing filter. This condition will resolve itself after flushing a couple of
tanks of water.
Step 7
Complete step #6 two more times. The process of flushing the system first three times
should take about one day to complete. The fourth tank can be used for drinking water.
Warning:
To prevent the possibility of electrical shock, clean up any water on
cabinet floor and dry all water from outside of RO unit.