background image

17

Limited Warranty  

This Reverse Osmosis System is warranted against defects in material and workmanship for a period of one year from the date of 

installation, not to exceed 1 year from the date of manufacture. Expendable items such as filter cartridges and membranes are not 

covered by this warranty.  
How to obtain Warranty Service: Contact the dealer that you purchased the system from. Watts will work in conjunction with our dealer 

to repair or replace at our discretion any unit that is determined to be defective. No returns will be accepted with out the proper return 

authorization number.  
What this warranty does not cover: This warranty does not cover defects resulting from improper installation, from  abuse, misuse, mis-

application, improper maintenance, neglect, alteration, accidents, casualties, fire, flood, freezing, environmental factors, water pressure 

spikes or other such acts of God.  
Return shipping charges are not included in this warranty and are the responsibility of the end user. 
This warranty will be void if defects occur due to failure to observe the following conditions: 
1. The Reverse Osmosis System must be hooked up to a potable municipal or well cold water supply. 
2. The hardness of the water should not exceed 10 grains per gallon, or 170 ppm. 
3. Maximum incoming iron must be less than 0.2 ppm. 
4. The pH of the water must not be lower than 2 or higher than 11 
5. The incoming water pressure must be between 40 and 100 pounds per square inch. 
6. Incoming water to the RO cannot exceed 105 degrees F (40 degrees C.) 
7. Incoming TDS/Total Dissolved Solids not to exceed 1000 ppm. 
8.  Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. 
This warranty does not cover any equipment that is relocated from the site of its original installation. 
This warranty does not cover any equipment that is installed or used outside the United States of America  

and Canada. 

LIMITATIONS AND EXCLUSIONS: 
WATTS WILL NOT  BE RESPONSIBLE FOR ANY  IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FIT-

NESS FOR A PARTICULAR PURPOSE. WATTS WILL NOT BE RESPONSIBLE  FOR ANY INCIDENTAL OR CONSEQUENTIAL DAM-

AGES, INCLUDING WATER DAMAGE, TRAVEL EXPENSE, TELEPHONE CHARGES, LOSS OF REVENUE, LOSS OF TIME, INCON-

VENIENCE, LOSS OF USE  OF THE EQUIPMENT, AND DAMAGE CAUSED BY THIS EQUIPMENT AND ITS FAILURE TO FUNCTION 

PROPERLY. THIS WARRANTY SETS FORTH ALL OF WATTS RESPONSIBILITIES REGARDING THIS  EQUIPMENT. 
OTHER CONDITIONS: 
If Watts chooses to replace the equipment, it may be replace with reconditioned equipment. Parts used in repairing or replacing the 

equipment will be warranted for 90 days from the date the equipment is returned to you or for the remainder of the original warranty 

period, whichever is longer. This warranty is not assignable or transferable.  

Summary of Contents for W-415-NF

Page 1: ...unsafe or of unknown quality without adequate disinfection before or after the system WARNING If you are unsure about installing your WATTS water filter contact a WATTS representative or consult a pr...

Page 2: ...rain saddle clamp 3 8 feed water valve faucet assembly 4 Manual Recommended Tools Lists Variable speed drill 1 8 and 1 4 drill bits 7 16 drill bit 1 2 and 9 16 open end wrenches or adjustable Phillips...

Page 3: ...on filter Auto shut off valve Operating pressure 40 100 PSI Operating temperature 40 100 F Please contact your local dealer at Replacement Parts WATTS ITEM DESCRIPTIONS SERVICE LIFE FPMB5 978 Sediment...

Page 4: ...bon filter Auto shut off valve Operating pressure 40 100 PSI Operating temperature 40 100 F Please contact your local dealer at Replacement Parts WATTS ITEM DESCRIPTIONS SERVICE LIFE FPMB5 978 Sedimen...

Page 5: ...age TFC membrane 50GPD 60 PSI 5th stage Inline carbon filter Auto shut off valve Operating pressure 40 100 PSI Operating temperature 40 100 F WATTS ITEM DESCRIPTIONS SERVICE LIFE FPMB5 978 Sediment fi...

Page 6: ...sition while the o ring provides a permanent leak proof seal 4 PULL TO CHECK SECURE Pull on the tube to check that it is secure It is a good practice to test the system prior to leaving site and or be...

Page 7: ...keep the drill bit cool If drill bit gets hot it may cause the porcelain to crack or chip 3 Using a 1 hole saw proceed to drill the large hole Keep drill speed on the slowest speed and use lubricating...

Page 8: ...to the 3 8 quick connect elbow on the polishing filter With Non Air Gap faucets this will be the only tube connected to the RO faucet Air Gap Faucet Follow the drinking feed tube connection instruc ti...

Page 9: ...n saddle near a garbage disposal may cause the drain line to plug 1 Gather the pieces of the drain saddle 1 Black compression nut 1 Semicircle bracket with opening 2 Screws 1 Foam gasket 2 Nuts for sc...

Page 10: ...all valve off TOP VIEW OF TANK BALL VALVE PPSV501222W OFF POSITION ON POSITION STEP 4 Mounting the Drain Clamp The drain saddle and part number to SC500B14 will fit most stan dard drain pipe It should...

Page 11: ...e local water temperature and water pressure NOTE During the fill period you may hear water trickling due to the Reverse Osmosis Process 4 After the Tank has filled open the RO Faucet to flush the tan...

Page 12: ...ty b Fill the tank sanitizer feeder with the recommended disinfectant dosage and connect the feeder to the water supply and RO storage tank c Turn on water supply and force water and disinfectant solu...

Page 13: ...pen the housing you may try unplugging the fitting between red tubing and the system in order to reduce the air and water pressure inside the housing 3 Filter and membrane change procedures a Shut off...

Page 14: ...te conversion of trivalent arsenic to pentavalent arsenic Please see the Arsenic Facts section of the Performance Data Sheet for further information Depending on water chemistry water temperature and...

Page 15: ...s of arsenic are potentially hazardous to your health trivalent arsenic is considered more harmful than pentavalent arsenic RO systems are very effective at removing pentavalent arsenic A free chlorin...

Page 16: ...in storage tank is low Normally it takes 2 3 hours to fill tank Low water pressure and or temperatures can reduce production rate Add pressure to storage tank The pressure should be 8 10 psi when the...

Page 17: ...m 4 The pH of the water must not be lower than 2 or higher than 11 5 The incoming water pressure must be between 40 and 100 pounds per square inch 6 Incoming water to the RO cannot exceed 105 degrees...

Page 18: ...18...

Page 19: ...19...

Page 20: ...stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FU...

Reviews: