10
<Fig 5>
STEP 3:
Mounting the Tank Ball Valve
Note: Do not tamper with the air valve on low side of storage
tank. It has been preset at 5-7 psi by the manufacturers.
1) With the provided teflon tape wrap 3-4 turns in a clockwise
direction around the male threaded connection on the top of the
storage tank,
2) Connect the ball valve to the thread. Make sure it is tight but not
over tight.
See <Fig. 5>.
3) Connect the yellow tubing from to the tank ball valve. Push the
tubing in all the way to make sure it is properly seated.
4) Turn the tank ball valve off.
TOP VIEW OF TANK BALL VALVE
(PPSV501222W)
OFF POSITION ON POSITION
STEP 4:
Mounting the Drain Clamp
The drain saddle and part number to (SC500B14) will fit most stan-
dard drain pipe ¼". It should be installed above the trap and on the
vertical tailpiece. See
<Fig. 6>
1) Position the drain saddle in desired location, mark spot through
thread outlet, remove saddle.
2) Drill ¼" (6.3mm) hole into the drain pipe above the water line of
trap.
3) Align the hole drilled in the drain pipe with the drain saddle using a
drill bit or other narrow straight object and tighten clamp.
4) Make sure to align drain saddle to drilled hole. Attach drain saddle
to drain pipe and tighten the two screws evenly. See
<Fig. 7>
.
5) Connect black tubing to drain clamp.