Notice:
If a Point of Leak Detector (POLD) is the cause of the alarm, the alarm condition must be cleared from the
POLD before clearing the alarm on the Control Panel.
OWNER’S MANUAL: CONTROL PANEL
Allows switching between the following Scenes: Home , Away , & Standby
WARNING putting the Leak Defense System into STANDBY may allow a leak to go undetected as it is
ignoring all water flowing
Water
Button:
Tapping the
Water
button allows you to
Turn Water On/Off
Time to Alarm
Icon:
Tapping the
Time to Alarm
icon allows you to set the amount of time water can flow before the Leak Defense
alarms in either the
Home
or
Away
Scene. Changing this while in
Standby
remaining before
Standby
ends
Trip Rate
Icon:
Tapping the
Trip Rate
icon allows you to set the percentage amount of water that can flow before the Leak
Defense begins its
Alarm Countdown
. This icon is not visible or changeable while in
Standby
Flow Arc
:
Tapping the middle of the circular flow graph brings up a menu with options to
Turn Water On/Off
, change
Scenes, and adjust the
Trip Rate
and
Time to Alarm
as well as check the Status of the system
Menu
Icon:
Tapping the
Menu
button allows you check WiFi settings, see connected Devices, see
Advanced
Settings, and
see the
Help
screen
Notification
Icon:
Will turn YELLOW if there is an issue. Shows numerous connection statuses
Scene Scheduling
Icon:
Shows if a
Scene Schedule
is running via web (set up through catchaleak.com or mobile app)
Override by API
Icon:
Shows if the current Scene is being set by an
API
or
GPI
(via 4-Hour Timer, Security system, Irrigation timer,
Pool fill interface, etc). Will be blue for
Away
scene, orange for
Standby
Low Water Temp
Icon:
Shows if
water temperature
falls below the predefined low temp threshold (default = 1°C)
High Water Temp
Icon:
Shows if
water temperature
exceeds the predefined high temp threshold (default = 80°C)
Low POLD Battery
Icon: Shows if the panel detects a
POLD low battery
signal. Note: If POLD is out of range or battery has dropped below
operating voltage, no alert will be received
WHEN LDS ALARMS:
When the LDS alarms you will see a red screen indicating the reason why the water has been shut off
Press
Silence
to silence the alarm sound while you check for leaks
If the cause of the alarm is known, press
Clear Alarm
to turn off alarm sound and follow the prompt to turn your
water back on
Scene
Button: