Permeate Pump Installation  

with the KWIK-CHANGE RO 

Parts Needed:

(1) 

1

4

" Plug Insert

(1) 

1

4

" Quick-Connect Union Tee

(1) 48" long, 

1

4

"  blue tubing

(1 - Optional) Inline Post Filter

NOTE:  When mounting the Permeate Pump, make sure the 

outlet ports of the Permeate Pump are above the inlet ports in 

order to allow entrapped air to escape

1.     Turn off the incoming water to the reverse osmosis unit. Lift the 

handle on the reverse osmosis drinking water faucet to drain the 

water from the system and storage tank .  

Note: If tank is equipped with a ball valve, close valve to pre-

serve the tank water.

2.     Before installing the Permeate Pump, remove the blue tube in-

serts from the ports . Refer to the diagram on Page 2 for instruc-

tions for disconnecting from a Quick-Connect fitting .

3 .     Locate the blue tube coming out of the elbow above the blue fil-

ter, then cut the tube 24" from the filters and insert the blue tube 

from the filter/manifold into the Permeate Pump “PERMEATE IN” 

port

4 .     Unplug and remove the blue tube located between the shutoff 

valve’s “OUT” port and the elbow above the green filter .  Insert a 

1

4

" plug into the elbow.

5 .     Use the additional blue tube and insert one end into the Perme-

ate Pump “PERMEATE OUT” port that the blue tube was just 

removed from .

6 .     Insert the other end of the additional blue tube into the shutoff 

valve’s “OUT” port that the blue tube was just removed from .

7 .     Cut the blue tube between the tank and shutoff valve and install 

1

4

" quick-connect union tee.

8 .     Insert the blue tube leading to the faucet into 

1

4

" Quick-Connect 

union tee

9 .     Locate  the 

1

4

" Red drain tube between the filters and faucet, 

and then cut the tube 24" from the filters.

10.    Insert the 

1

4

" Red drain tube, from the filters, into the Permeate 

Pump “BRINE IN” port (making sure to leave the flow restrictor 

end of the tube plugged into the filter port.)

11.    Insert the 

1

4

" Red drain tube, from the faucet, into the Permeate 

Pump “BRINE OUT” port.

12.    Make sure your installation matches the diagram shown in  

Figure 3

13.    (Optional) Locate the 

1

4

" Blue tube between the faucet and 

Quick-Connect union tee and install the inline post filter

 Installation Steps

Summary of Contents for PWPERMKIT

Page 1: ...with the Manifold System 4 5 Permeate Pump Installation with the KWIK CHANGE RO 6 7 Limited Warranty 8 PWPERMKIT PURE WATER Important Please read the entire manual before proceeding with the installat...

Page 2: ...indicate how far the tube should be inserted The unique Watts Quick Connect locking system holds the tube firmly in place without deforming it or restrict ing flow Cut the tube square It is essential...

Page 3: ...the membrane housing Then insert the end from the reverse osmosis mem brane into the Permeate Pump PERMEATE IN port 4 Insert the tube from the shutoff valve into the Permeate Pump PERMEATE OUT port U...

Page 4: ...disconnecting from a Quick Connect fitting 3 Remove the 3 8 Blue tube from the manifold TANK port and insert the 3 8 Plug 4 Locate the 3 8 Blue tube from the manifold FAUCET port and cut approximatel...

Page 5: ...5 Figure 2 Manifold System after installation of Permeate Pump RED FLOW RESTRICTOR BLUE GREEN BLUE BLUE BLUE BLUE BLUE RED RED RED 3 8 BLACK TUBE DRAIN...

Page 6: ...4 Unplug and remove the blue tube located between the shutoff valve s OUT port and the elbow above the green filter Insert a 1 4 plug into the elbow 5 Use the additional blue tube and insert one end i...

Page 7: ...7 Figure 3 KWIK CHANGE RO after installation of Permeate Pump RED TUBE RED TUBE BLUE TUBE BLUE TUBE GREEN TUBE BLUE TUBE...

Page 8: ...warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PER...