Installation, Operation  
and Maintenance Manual

Ultra Violet Disinfection System
Series PWUV

IOM-WQ-PWUV

Important

Please read the entire manual before proceeding with the  

installation and startup. Your failure to follow any attached 

instructions or operating parameters may lead to the product’s 

failure. Water must be prefiltered by a minimum of 5 micron 

filtration.
Save manual for future reference.

Series PWUV

PURE WATER

Table of Contents

Installation  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2
Specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Replacing UV Lamp .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Maintenance Suggestion  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Operating Conditions .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
Parts List / Unit Drawing   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4
Limited Warranty  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

Note:

 Do not use with water that is microbiologically unsafe or 

of unknown quality without adequate disinfection before or after 

the system . 

Summary of Contents for PURE WATER PWUV Series

Page 1: ...ameters may lead to the product s failure Water must be prefiltered by a minimum of 5 micron filtration Save manual for future reference Series PWUV PURE WATER Table of Contents Installation 2 Specifications 3 Replacing UV Lamp 3 Maintenance Suggestion 3 Operating Conditions 3 Parts List Unit Drawing 4 Limited Warranty 4 Note Do not use with water that is microbiologically unsafe or of unknown qua...

Page 2: ...lide the quartz sleeve into the chamber closed end first c Slide the O ring over the open end of the quartz sleeve d Tighten the retainer nut hand tight e Slide the lamp into the quartz sleeve f Connect the lamp to the plug in transformer g Cover the lamp connection with the vinyl cap 7 Turn on the water and inspect for leaks Repair if necessary 8 a For 110 VAC Units Plug the transformer into an e...

Page 3: ... Carefully remove O ring from the end of quartz sleeve Step 8 Carefully remove quartz sleeve Step 9 To reinstall follow Steps 8 through 1 in reverse Maintenance Suggestion To operate the sterilizer properly and attain its maximum efficiency the following maintenance is recommended 1 Quartz sleeve cleaning or replacement a Quartz sleeve is to be cleaned every 6 12 months clean with glass cleaner b ...

Page 4: ...terature that comes with your product Any remedies stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW WATTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE ...

Reviews: