background image

iteM

deScriPtion

1

Ballast Assembly

2

Germicidal Ultraviolet Lamp

3

Rubber O-ring

4

Quartz Sleeve

5

Chamber

6

Mounting Clip

 Parts List

IOM-WQ-PWUV   1225 

EDP# 2915895 

© 2012 Watts

USA:  

Tel. (800) 224-1299 • www .watts .com 

Canada: 

 Tel. (888) 208-8927 • www .watts .ca

A Watts Water Technologies Company

liMited warrantY:

  Certain Watts Pure Water products come with a limited warranty from Watts Regulator Co.  Other products may have no warranty or are covered by the original manufacturer’s  

warranty only.  For specific product warranty information, please visit www.watts.com or the published literature that comes with your product.  Any remedies stated in such warranties are exclusive and 

are the only remedies for breach of warranty.  

eXcePt For tHe aPPlicable Product warrantY, iF anY, wattS MaKeS no otHer warrantieS, eXPreSS or iMPlied. to tHe FulleSt eXtent 

PerMitted bY aPPlicable law, wattS HerebY SPeciFicallY diSclaiMS all otHer warrantieS, eXPreSS or iMPlied, includinG but not liMited to tHe iMPlied warrantieS oF 

MercHantabilitY and FitneSS For a Particular PurPoSe, and in no eVent SHall wattS be liable, in contract, tort, Strict liabilitY or under anY otHer leGal tHeorY, For 

incidental, indirect, SPecial or conSeQuential daMaGeS, includinG, witHout liMitation, loSt ProFitS or ProPertY daMaGe, reGardleSS oF wHetHer it waS inForMed about 

tHe PoSSibilitY oF SucH daMaGeS. 

Summary of Contents for PURE WATER PWUV Series

Page 1: ...ameters may lead to the product s failure Water must be prefiltered by a minimum of 5 micron filtration Save manual for future reference Series PWUV PURE WATER Table of Contents Installation 2 Specifications 3 Replacing UV Lamp 3 Maintenance Suggestion 3 Operating Conditions 3 Parts List Unit Drawing 4 Limited Warranty 4 Note Do not use with water that is microbiologically unsafe or of unknown qua...

Page 2: ...lide the quartz sleeve into the chamber closed end first c Slide the O ring over the open end of the quartz sleeve d Tighten the retainer nut hand tight e Slide the lamp into the quartz sleeve f Connect the lamp to the plug in transformer g Cover the lamp connection with the vinyl cap 7 Turn on the water and inspect for leaks Repair if necessary 8 a For 110 VAC Units Plug the transformer into an e...

Page 3: ... Carefully remove O ring from the end of quartz sleeve Step 8 Carefully remove quartz sleeve Step 9 To reinstall follow Steps 8 through 1 in reverse Maintenance Suggestion To operate the sterilizer properly and attain its maximum efficiency the following maintenance is recommended 1 Quartz sleeve cleaning or replacement a Quartz sleeve is to be cleaned every 6 12 months clean with glass cleaner b ...

Page 4: ...terature that comes with your product Any remedies stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW WATTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE ...

Reviews: