background image

3

Specifications

Notes: Line cord and lamp lead wire omitted for clarity .

Product code

 Flow rate

(GPM)

PiPe Size

diMenSionS

(l X w X H)

electrical

 SHiPPinG

(lbS.)

PWUV2110

2

1

2

" MNPT

18" x 6" x 5

3

8

110-130 v / 50-60 Hz 

6

PWUV2220

2

1

2

" MNPT

18” x 6” x 5

3

8

"

200-250 v / 50-60 Hz

6

PWUV6110

6

3

4

" MNPT

25

1

2

" x 6” x 5

3

8

"

110-130 v / 50-60 Hz

7

PWUV6220

6

3

4

" MNPT

25

1

2

" x 6” x 5

3

8

"

200-250 v / 50-60 Hz

7

PWUV8110

8

3

4

" MNPT

32" x 8

1

4

" x 3

3

4

"

110-130 v / 50-60 Hz

9

PWUV8220

8

3

4

" MNPT

32" x 8

1

4

" x 3

3

4

"

200-250 v / 50-60 Hz

9

PWUV12110

12

1" MNPT

41

1

2

" x 8

1

4

" x 3

3

4

"

110-130 v / 50-60 Hz

17

PWUV12220

12

1" MNPT

41

1

2

" x 8

1

4

" x 3

3

4

"

200-250 v / 50-60 Hz

17

Replacing UV Lamp and Servicing 

UV System

Note: Avoid touching the sides of the quartz sleeve and lamp, 

handle by the ends only.

 Step 1  Disconnect power .
 Step 2   Turn water off and open valve downstream of system to 

relieve pressure .

 Step 3  Remove vinyl cap and unscrew the nut .
 Step 4   Carefully withdraw lamp approximately 2 inches from 

chamber .

 Step 5   While holding lamp end carefully remove lamp socket on 

end now exposed .

 Step 6  Carefully withdraw lamp from chamber .
 Step 7  Carefully remove O-ring from the end of quartz sleeve .
 Step 8  Carefully remove quartz sleeve .
 Step 9  To reinstall follow Steps 8 through 1 in reverse .

Maintenance Suggestion

To operate the sterilizer properly and attain its maximum efficiency, 

the following maintenance is recommended:
 1 .  Quartz sleeve cleaning or replacement:
    a)  Quartz sleeve is to be cleaned every 6-12 months, clean with 

glass cleaner .

    b) Quartz sleeve is to be replaced every 24 months .
 2 .    UV lamp replacement is recommended every 8000-9000 hours 

of operation (approx . 12 months of continuous service) .

CAUTION: Ultraviolet lamp and quartz sleeve are easily dam-

aged. Pay attention when removing or replacing lamp and 

quartz sleeve.

Operating Conditions

Maximum Operating Pressure:  125psi (8 .9 bar)
Maximum Operating Temperature:  104°F (40°C)
Minimum Operating Temperature:  36°F (2°C)
UV Dose At End Of Lamp Life (1 year or 9,000 Hours):  30mj/cm

2

Maximum Iron:  Less Than  .3 PPM
Maximum Manganese:  Less Than  .05 PPM
Maximum Turbidity:  Less Than 5 NTU
Maximum Hydrogen Sulfide:  Less Than  .05 PPM
Maximum Hardness:  Less Than 7 Grains Per Gallon as CaCO

3

Flow 

rate 

(GPM)

bulb Model

ballaSt Model

Quartz SleeVe Model

2

PWUVBULB2

PWUVBAL2

PWUVQS2

6

PWUVBULB6

PWUVBAL6-12

PWUVQS6

8

PWUVBULB8

PWUVBAL6-12

PWUVQS8

12

PWUVBULB12

PWUVBAL6-12

PWUVQS12

Replacement Parts

Summary of Contents for PURE WATER PWUV Series

Page 1: ...ameters may lead to the product s failure Water must be prefiltered by a minimum of 5 micron filtration Save manual for future reference Series PWUV PURE WATER Table of Contents Installation 2 Specifications 3 Replacing UV Lamp 3 Maintenance Suggestion 3 Operating Conditions 3 Parts List Unit Drawing 4 Limited Warranty 4 Note Do not use with water that is microbiologically unsafe or of unknown qua...

Page 2: ...lide the quartz sleeve into the chamber closed end first c Slide the O ring over the open end of the quartz sleeve d Tighten the retainer nut hand tight e Slide the lamp into the quartz sleeve f Connect the lamp to the plug in transformer g Cover the lamp connection with the vinyl cap 7 Turn on the water and inspect for leaks Repair if necessary 8 a For 110 VAC Units Plug the transformer into an e...

Page 3: ... Carefully remove O ring from the end of quartz sleeve Step 8 Carefully remove quartz sleeve Step 9 To reinstall follow Steps 8 through 1 in reverse Maintenance Suggestion To operate the sterilizer properly and attain its maximum efficiency the following maintenance is recommended 1 Quartz sleeve cleaning or replacement a Quartz sleeve is to be cleaned every 6 12 months clean with glass cleaner b ...

Page 4: ...terature that comes with your product Any remedies stated in such warranties are exclusive and are the only remedies for breach of warranty EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY IF ANY WATTS MAKES NO OTHER WARRANTIES EXPRESS OR IMPLIED TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW WATTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE ...