2
Installation Instructions
1 . Install sterilizer equipment in a readily accessible and well lit
location to facilitate inspection and maintenance .
2 . Inspect for hidden electrical wiring or plumbing prior to drilling
holes .
3 . Attach mounting clips to the wall .
4 . Insert chamber through mounting clips .
5 . Connect to plumbing .
6 . Install quartz sleeve and lamp .
Note: Avoid touching the sides of the quartz sleeve and lamp,
handle by the ends only.
a) Remove the retainer nut .
b) Slide the quartz sleeve into the chamber - closed end first .
c) Slide the O-ring over the open end of the quartz sleeve .
d) Tighten the retainer nut, hand tight .
e) Slide the lamp into the quartz sleeve .
f) Connect the lamp to the plug in transformer .
g) Cover the lamp connection with the vinyl cap .
7 . Turn on the water and inspect for leaks . Repair if necessary .
8 . a) For 110 VAC Units – Plug the transformer into an electrical
outlet . An electrical outlet protected by a Ground Fault Circuit
Interrupt (GFCI) circuit is recommended .
b) For 220 VAC Units – Obtain the appropriate plug for your type
of receptacle and attach it to the end of the power cord and
plug it in .
Typical Installation