background image

4

Table of Contents 

Page

Safety Information  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
How To Use This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Project Data Sheet  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
System Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 –7
Set Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Operating Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
System Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9–10
Start Up Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Installation Diagrams - Series HC-200 Simplex Systems  . . . . .11
Installation Diagrams - Series HCTA-200  

Duplex Alternating Systems . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Installation Diagrams - Series HCP-200  

Progressive 2-4 Tank Systems. . . . . . . . . . . . . . . . . . . . . . . . .13
Controller Electrical Connections . . . . . . . . . . . . . . . . . . . . . . .14
Wiring Diagram  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
NXT2 Controller Programming and Operation  . . . . . . . . . . . . .16
Controller Display  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Controller Operation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
Controller Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19–20
Master Programming Mode Flow Chart . . . . . . . . . . . . . . . 21–22
User Programming Mode Flow Chart. . . . . . . . . . . . . . . . . . . .22
Diagnostic Programming Mode Flow Chart  . . . . . . . . . . . . . . .23
Time of Day Programming Mode Flow Chart . . . . . . . . . . . . . .24
NXT2 Programming Parameters and Ranges. . . . . . . . . . . . . .25
Replacing the Media  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Replacement Parts - Major System Components  . . . . . . .27–28
Replacement Parts - 2900 Upper Powerhead . . . . . . . . . . . . .29
Replacement Parts - NXT2 Controller Assembly  . . . . . . . . . . .30
NXT to NXT2 Conversion Kit  . . . . . . . . . . . . . . . . . . . . . . . . . .31
Replacement Parts - 2900 Lower Powerhead . . . . . . . . . . . . .32
Replacement Parts - 2900S Control Valve Body  . . . . . . . . . . .33
Replacement Parts - 1600 Brine System . . . . . . . . . . . . . . . . .34
Replacement Parts - 1650 Brine System . . . . . . . . . . . . . . . . .35
Replacement Parts - 1700 Brine System . . . . . . . . . . . . . . . . .36
Replacement Parts - 1710 Brine System . . . . . . . . . . . . . . . . .37
Replacement Parts - 2" Stainless Steel Electronic Meter  . . . . .38
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39–40
Water Softener Flow Diagrams  . . . . . . . . . . . . . . . . . . . . .41– 42
Flow Data and Injector Draw Rates - Down Flow . . . . . . . . . . .43
Injector Nozzle and Throat Chart  

for 1600/1700 Brine Systems  . . . . . . . . . . . . . . . . . . . . . . . . .44
Warranty  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .44

Introduction

Principals of Softening- Ion Exchange

In nature, water acts as a solvent that dissolves substances it 

comes in contact with such as solid rock. When water dissolves 

limestone rock, which is composed of calcium and magnesium, 

the solid calcium and magnesium become ions. This means 

they have been dissolved into the water and are now a liquid. An 

ion with a positive electrical charge is called a cation. Calcium 

and magnesium hardness ions in water are positively charged 

cations. When water dissolves enough calcium and magnesium 

hardness cations it is classified as hard water, which can cause 

lime scale build up in plumbing systems, water spots, and an 

increase in soap and cleaning product usage.
Ion exchange water softening is a process where an ion 

exchange resin is used to effectively exchange calcium and  

magnesium hardness cations for sodium cations in the water.
New, or freshly regenerated, ion exchange resin is saturated with 

sodium cations. As calcium and magnesium hardness cations 

come in contact with the ion exchange resin, they attach to the 

resin and sodium cations are released into the water. This is pos-

sible because the hardness cation are more attracted to the ion 

exchange resin than the sodium cations. Therefore, scale form-

ing calcium and magnesium cations have been exchanged for 

non-scale forming sodium cations as the water is treated. If the 

calcium and magnesium content of the water is reduced to less 

than 17.1 mg/L, that water is classified as soft water.
Eventually the ion exchange resin will become exhausted, depleted 

of sodium, and will need to be regenerated with a sodium brine 

solution to restore its capacity to soften water. This system 

includes a flow meter to track treated water volume and initiate 

the regeneration process before resin exhaustion occurs.

Regeneration occurs automatically and consists of 5 steps:

Step 1- Backwash

Approximate Duration 10 Minutes- Fresh water flow is directed 

upward through the resin bed, to remove solid particles the resin 

bed has captured, sending them to drain.

Step 2- Brine Draw

Approximate Duration 15-20 Minutes- Brine water is drawn from 

the brine tank, rinsed over the ion exchange resin, driving away 

the calcium and magnesium cations and restoring sodium cations 

within the resin. Calcium and magnesium is sent to drain.

Step 3- Slow Rinse

Approximate Duration 40-45 Minutes- Once the brine tank is 

emptied of brine water, fresh water will continue to rinse over  

the resin and rinse calcium and magnesium cations to drain.

Step 4- Rapid Rinse

Approximate Duration 10 Minutes- After the conclusion of slow 

rinse, fresh water will rinse over the resin to ensure any residual 

sodium brine has been cleaned from the resin before it returns  

to service.

At the conclusion of Rapid Rinse:
Simplex single tank systems return to the “In Service” position. 

Multi tank systems remain in the “Stand By” position.

Step 5- Brine Tank Refill

Approximate Duration User Adjustable- In this final step of  

regeneration, water is added back into the brine tank so that  

a brine solution can be prepared for the next regeneration.

Summary of Contents for HC-200 Series

Page 1: ...Installation Operation and Maintenance 2 Commercial Water Softeners Series HC 200 HCTA 200 HCP 200 HC 200 Simplex Systems HCTA 200 Duplex Alternating Systems HCP 200 Duplex Triplex and Quadplex Progre...

Page 2: ...ality components Simple programming corrosion resistant mineral tank s and an easy to service design ensures this system will be durable and easy to maintain Thank You The Watts Team Softened water pr...

Page 3: ...r that is microbiologically unsafe or of unknown quality This system will not make microbiologically unsafe water safe Water that is unsafe must be treated separately from this conditioner Operating a...

Page 4: ...exchange water softening is a process where an ion exchange resin is used to effectively exchange calcium and magnesium hardness cations for sodium cations in the water New or freshly regenerated ion...

Page 5: ...neration B System 7 2 Mineral Tanks 1 Meter Immediate Regeneration C System 14 2 8 Mineral Tanks 2 8 Meters Immediate Regeneration Progressive Flow Tank Staging GPM Threshold for Progressive Feature _...

Page 6: ...2184 977 16 2449 361 8 917 361 8 917 39 991 60 1524 1560 709 Series HCTA 200 MODEL NO DIMENSIONS WEIGHTS A B C D E F G in in in mm in mm in mm in mm in mm in mm lbs kgs M4043TA 29NT 673 8 1711 673 8 1...

Page 7: ...EL NO ORDERING CODE DESCRIPTION SPACE REQUIRED WEIGHT D X W X H LBS M4043TI NH 68110194 3 Cubic Foot 2 Progressive Duplex Softener with Flow Meters 38 x 55 x 87 530 M4047TI NH 68110195 4 Cubic Foot 2...

Page 8: ...rding to the diagram below according to your specific series number If any components are missing or damaged contact your Watts representative If they can not be reached contact Watts customer service...

Page 9: ...with the top of the tank Test the tape cap to make sure it can not come off during the media loading process 4d For systems 24 in diameter and larger fill the mineral tank 1 3 full with water to prev...

Page 10: ...P14 port s of the control valve controller s See pages 14 15 for P14 location 18 If applicable install a metal bonding strap across metal inlet and outlet plumbing lines to maintain electrical contin...

Page 11: ...te and local codes Do not construct drain line to elevations that exceed 4 feet above the control valve s drain port 11 The full weight of the piping and valves must be supported by pipe hangers or ot...

Page 12: ...12 Installation Diagrams Series HCTA 200 Duplex Alternating Systems Top View Side View Front View...

Page 13: ...13 Installation Diagrams Series HCP 200 Progressive 2 4 Tank Systems Top View Side View Front View...

Page 14: ...Power Supply 3150 3900 Valves Wire Harness Meter Cable Power Supply Communication Cables Hinge Mount mount per valve model noted 44404 Rev A 44403 Rev A HC 200 HCTA 200 HCP 200 Systems use 2900 2900S...

Page 15: ...15 Wiring Diagram 44403 Rev A Wiring diagrams are reference only All wiring should be done by a certified electrician and meet all electrical codes...

Page 16: ...menu navigation Network two to eight valves via shielded CAT5 cables LED Status Indicator Blue In Service Flashing Blue Regeneration Queued Green Regeneration Flashing Green Standby Red Error conditio...

Page 17: ...17 Controller Display...

Page 18: ...egeneration If regeneration occurs for any reason prior to the delayed regeneration time the manual regeneration request shall be cleared Pressing the Extra Cycle button while in regeneration will cau...

Page 19: ...ote Regeneration Ability to trigger a regeneration via a remote input Regeneration Types Softener Filter Meter Delayed When volume remaining reaches zero and the scheduled regeneration time is reached...

Page 20: ...n the NXT2 circuit board Activates during selected cycle step Activates upon selected start time Range 0 91 minutes Deactivates upon selected end time Range Start Time plus 1 minute Activates when sel...

Page 21: ...amming certain values may not be able to be viewed or set 7 The controller will display local information not system information 8 In the event of a regeneration occurring while displaying mas ter pro...

Page 22: ...e button to advance to the next value Press the Left button to retreat to the previous value 3 Where applicable use the Up and Down buttons to adjust a value as desired 4 After progressing through all...

Page 23: ...splayed When regeneration has been completed the display will return to the main screen Example Real time flow rate reading Example Peak flow since last regeneration Example Gallons at the outlet sinc...

Page 24: ...n buttons to adjust as desired 3 Press the Extra Cycle button to advance to the Month field Press the Up or Down buttons to adjust as desired 4 Press the Extra Cycle button to advance to the Calendar...

Page 25: ...X X X X X X X Off Immediate Delayed Auxiliary 1 2 X X X X X X X X X X Off Alarm Based Cycle Based Time Based Lock Window 1 2 X X X X X X X X X X On Off Meter Type X X X X X X X X Paddle 0 75 1 1 5 2...

Page 26: ...the other end of the hose inside a water permeable bag and locate the bag over the floor drain 14 Insert a garden hose into the bag side of the poly vinyl hose to fill the hose and PVC pipe with wate...

Page 27: ...ON 5 0 GPM F 14 SOFTENER 3 1 68108571 V7103 07 FC BUTTON 7 0 GPM F 16 SOFTENER 3 1 68108574 V7103 10 FC BUTTON 10 0 GPM F 18 SOFTENER 3 1 68108575 V7103 12 FC BUTTON 12 0 GPM F 21 SOFTENER 3 1 6810857...

Page 28: ...3E BRINE TANK ASSY 24X41 BLK W GRID AIR CHECK FOR 1 2 BRINE HOSE 13 1 68102503 G2004B BRINE TANK ASSY 24X50 BLK W GRID AIR CHECK FOR 1 2 BRINE HOSE 13 1 68102512 G2009A BRINE TANK ASSY 30X50 BLK W AIR...

Page 29: ...00 Upper Powerhead 2900 UPPER POWERHEAD ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104633 K4560410 NT UPPER POWERHEAD F 2900S 24V NXT2 W POWER SUPPLY NO TIMER 2 1 68104575 K4560219 02 COVER FOR 2750 29...

Page 30: ...30 NXT2 Controller Assembly NXT2 CONTROLLER ASSEMBLY ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104777 K4562115 CONTROLLER ASSEMBLY NXT2 1...

Page 31: ...31 NXT to NXT2 Conversion Kit NXT TO NXT2 CONVERSION KIT ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104778 K4562121 01 CONTROLLER ASSY CONV KIT NXT TO NXT2 W 24V US POWER SUPPLY 1...

Page 32: ...rts 2900 Lower Powerhead 2900 LOWER POWERHEAD ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104635 K4560411 NT LOWER POWERHEAD F 2900S 24V NTXT2 NO COVER 2 1 68104574 K4560217 02 COVER FOR 2900 LOWER POWE...

Page 33: ...DOWNFLOW F 2900S UPPER 4 1 68104546 K4560128 SEAL SPACER KIT F 2900S LOWER 5 1 68104732 K4561550 PISTON ASSEMBLY DOWNFLOW HWBP F 2900S LOWER 5 1 68104733 K4561555 PISTON ASSEMBLY DOWNFLOW NHWBP F 2900...

Page 34: ...BRINE FLOW WASHER 25 GPM 5 1 68104118 K4512095 BRINE FLOW WASHER 50 GPM 5 1 68104119 K4512097 BRINE FLOW WASHER 1 0 GPM 6 1 68104079 K4510913 00 INJECTOR NOZZLE 00 VIOLET 6 1 68104080 K4510913 000 INJ...

Page 35: ...00 INJECTOR NOZZLE 00 VIOLET 5 1 68104080 K4510913 000 INJECTOR NOZZLE 000 BROWN 5 1 68104081 K4510913 BL INJECTOR NOZZLE 2 BLUE 5 1 68104082 K4510913 G INJECTOR NOZZLE 4 GREEN 5 1 68104083 K4510913 R...

Page 36: ...1 7CB INJECTOR NOZZLE 7C BLACK 3 1 68104214 K4514802 3Y INJECTOR THROAT 3C YELLOW 3 1 68104215 K4514802 4G INJECTOR THROAT 4C GREEN 3 1 68104216 K4514802 5W INJECTOR THROAT 5C WHITE 3 1 68104217 K4514...

Page 37: ...04109 K4512085 FLOW CONTROL WASHER 1 2 GPM 2 1 68104110 K4512086 FLOW CONTROL WASHER 1 5 GPM 2 1 68104111 K4512087 FLOW CONTROL WASHER 2 0 GPM 2 1 68104112 K4512088 FLOW CONTROL WASHER 2 4 GPM 2 1 681...

Page 38: ...h Electronic Meter 2 INCH STAINLESS STEEL METER ASSY ITEM NO QTY PART NUMBER DESCRIPTION 1 1 68104756 K4561934 10 METER ASSEMBLY COMPLETE 2 STAINLESS STEEL MECH ELEC 2 1 68104199 K4514716 METER DOME P...

Page 39: ...generation Inlet of control plugged due to foreign material broken loose from pipes by recent work done on plumbing system Remove piston and clean control valve Loss of mineral through drain line Air...

Page 40: ...ected system type in Master Programming Push correct valve settings in Master Settings Motor Stall No Changes Detected in the Optical Sensor for 6 Seconds The motor is on but no encoder pulses are det...

Page 41: ...41 Water Softener Flow Diagrams Down Flow Brining 2 Backwash Position 3 Brine Position 4 Slow Rinse Position 5 Rapid Rinse Position 6 Brine Tank Refill Position 1 Service Position...

Page 42: ...42 Water Softener Flow Diagrams Up Flow Brining 2 Brine Position 3 Slow Rinse Position 4 Backwash Position 5 Rapid Rinse Position 6 Brine Tank Fill Position 1 Service Position...

Page 43: ...43 Flow Data and Injector Draw Rates Down Flow...

Page 44: ...ilox Micro Z and neutralizing media are also not covered by this warranty In the event of a covered defect within the warranty period the Company will at its option replace or recondition the product...

Reviews: