Page 6

AG-SS with Monitor Faucet Installation

Step 6

Step 7

Step 8

Gather and identify the M-500 faucet pieces.

Step 10

Note:

A dripping or gurgling sound may be heard coming from the air gap hole on the faucet or
the drain when the system is running.  This is normal and in compliance with UPC
(Universal Plumbing Code) requirements.

If using the  AG-SS Monitor Air Gap Faucet , a 1 1/4" hole will be
required.

Remove Faucet and small parts from plastic bag.
Slip the Gasket over the threaded Stem to the Faucet Flange.
From above the sink, feed the tubing and Faucet Stem down
through the 1

¼ 

inch mounting hole in the Sink.

From below the sink, slide the Tubing Guide up the threaded Stem
and follow it with the Mounting Nut, turning the nut clockwise until
fully tightened.

Press the blue colored Product Water Tubing, coming
from the RO purification system into the end of the
threaded Stem. Push it all the way in and then pull on it
firmly to verify it is locked in place.

Refer to 

Black Tube Connection

 and 

Red Tube

Connection

 steps in this manual to complete the faucet

installation.
.Remove the Spout from the top of the Faucet by pulling it straight
upward. SEE DRAWING
Remove the Faucet Knob by pinching the two locking tabs inward
and then pulling upward on the Knob while the tabs are pinched
inward. Push the coin cell Battery into the Battery Holder behind the
Circuit Board. 

NOTE:  the + side of the Battery goes against the

Gold metal bracket.

Replace the Knob by centering it over the Faucet and aligning the
trough on the inside of the Faucet Knob with the Valve Lever.
Lower the Knob making sure the Valve Lever slides into the trough,
making sure the Knob top hole is centered over the locking tabs.
Push the Knob all the way down until it locks in place.
Push the Spout back into the top of the Faucet so that it is fully
seated and push the frosted Deflector down until fully seated. You
may have to rotate the Deflector until it is in position to be fully
seated.

With the Knob rotated to the Right about ½ inch, turn the source
water to your RO purification system on and check for leaks. You
should see the Green light flash at the base of the Faucet while water
is flowing through the Faucet 

(red light may flash when system is

initially producing water, this will turn green following the
initial tank flush)

.  When you see the Red light flash, it means it is

time to replace your filter cartridge(s).
Turn the Knob to the left until water stops flowing and check for leaks.

Step 9

Step 11

Step 12

Step 13

Note:

Summary of Contents for 5 SV DELUXE

Page 1: ...C 20 Phoenix AZ 85027 Phone 800 752 5582 www wattspremier com Fax 623 931 0191 Save manual for future reference MODELS Warning Please read carefully before proceeding with installation Your failure t...

Page 2: ...erse Osmosis System 4 Tools Recommended For Installation 4 Drill a Hole for the Faucet in a Porcelain Sink 5 Punch a Hole for the Faucet in a Stainless Steel Sink 5 Faucet Installation 6 Adapta Valve...

Page 3: ...8 Open End Wrenches Phillips Screw Driver Needle Nose Pliers Adjustable Pliers Electric Drill 1 8 1 4 3 8 Drill Bits Contents of Reverse Osmosis System s e r u t a r e p m e T g n i t a r e p O C 8 7...

Page 4: ...rface material is extremely hard and can crack or chip quite easily Use extreme caution when drilling Premier Manufactured Systems accepts no responsibility for consequential damage resulting from the...

Page 5: ...r as shown A slotted washer is used if it is a non air gap faucet Thread the black stem nut back onto the white threaded stem and thighten within of plastic spacer Check the orientation of the faucet...

Page 6: ...EE DRAWING Remove the Faucet Knob by pinching the two locking tabs inward and then pulling upward on the Knob while the tabs are pinched inward Push the coin cell Battery into the Battery Holder behin...

Page 7: ...ttom of the cabinet Step 11 Step 12 Attach adapta valve as illustrated in the three photos above choosing the configuration that fits your plumbing When attaching the adapta valve to straight pipe thr...

Page 8: ...n pipe Insert screw driver into the opening of the drain saddle and align with drilled hole in drain pipe Using Philips screw driver tighten screws evenly and securely on both sides of the drain saddl...

Page 9: ...ten Step 19 Step 21 Blue Tube Connection Position tank in desired location Stand it upright or lay it on its side using the black plastic stand Measure the blue tube from the RO module over to the tan...

Page 10: ...possible making a downward slope from faucet to drain saddle to allowfor proper drainage Step 25 Note Step 26 Step 27 Red Tube Connection Using the white plastic union in the parts bag determine where...

Page 11: ...ilter Installation If the system has a 6 final filter refer to the 6 inch final filter installation If the 6 final filter has already been installed skip this section Remove the 2 blue caps from the 1...

Page 12: ...remove carbon particles from final filter There is an average of 4 gallons of reject water for every 1 gallon of product water produced Step 6 Open the RO faucet and leave it open until water begins t...

Page 13: ...e water inlet connects 6 Month System Maintenance Turn off incoming water supply to the RO at needle valve on adapta valve Step 1 Step 3 Step 4 Step 5 Step 6 Let system sit for 10 15 minutes after tan...

Page 14: ...11 Annual Maintenance Watts Premier sells a filter change kit which includes pre filters orings a final filter connectors and a wrench Call 1 800 752 5582 or buy online at www wattspremier com Perform...

Page 15: ...an containers Clearly mark each container Watts Premier will test the water and call or mail you the results To change the membrane use a 5 8 wrench to remove the Green Tube on the left side of the me...

Page 16: ...of Housing Note Step 10 Follow the Start Up Instructions Check air pressure when tank is empty Check Air Pressure in the Tank Using a digital air gauge check the air pressure in the tank You should a...

Page 17: ...c o l r e p o r p r o f m a r g a i d e e S e b u t n i a r d n i n o i t c i r t s e R m o r f s i r b e d y b d e s u a c s e m i t e m o s e g a k c o l b r a e l C r e h s a w h s i d r o l a s o...

Page 18: ...10005 MEM TFM 25 GPD DRY 5 a 113004 LID BLACK 1 4 FPT UNASSEMBLED 5 b 113007 LID WHITE 1 4 FPT UNASSEMBLED 6 a 113017 HOUSING FILTER 10 BLUE 6 b 113024 HOUSING FILTER 10 WHITE 7 113032 VESSEL MEM HOUS...

Page 19: ...Page 19 California Certification...

Page 20: ...0 1 Copper Reduction 3 1 mg L 0 03 mg L 99 0 7 64 50psi 0 04 3 0 10 1 3 Cysts 222 077 ml 10 ml 99 99 58 minimum 50 000 mL Fluoride Reduction 8 0 mg L 0 5 mg L 93 9 7 49 50psi 0 7 8 0 10 1 5 Lead Reduc...

Page 21: ...e including a 10 polishing filter instead of a 6 Part No 560066 31 95 Kit Premium Filter replacement kit Compatible with all Watts Premier Reverse Osmosis and other water filtration systems These filt...

Page 22: ...ontinuous trouble free operation Part No 107001 64 95 ea Water Pressure Gauge This gauge mounts onto your outside hose connection to accurately show your home s water pressure up to 300 psi A red need...

Page 23: ...t No 107091 CHROME 44 95 Part No 107075 14 95 pk Part No 107092 GOLD 48 95 Shower Falls Deluxe Shower Handle with Built in Filter Curved Ergonomic Shower Handle Filter Handle Extension Replacement fil...

Page 24: ...Page 24...

Page 25: ...ter your information XX XXXXXX Watts Premier Inc is concerned for the saftey of your personal information Watts Premeir collects personal information when you register with Watts Premier This informat...

Page 26: ...State _______________________________________ Zip Code ___________________ Country USA CANADA MEXICO OTHER ____________ Phone ______ __________ __________ Email Address ______________________ Date of...

Page 27: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Page 28: ...inch 6 Incoming water to the RO cannot exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of un...

Reviews: